J Otolaryngol Ophthalmol Shandong Univ ›› 2013, Vol. 27 ›› Issue (4): 26-31.doi: 10.6040/j.issn.1673-3770.0.2013.193

• Articles • Previous Articles     Next Articles

Characteristics of thin corneal flaps created with Wavelight FS200 femtosecond laser

HAO Ying-juan1, YANG Qing-song2, ZHOU Yue-hua2,  YI Sheng-ping1, ZHAI Chang-bin2   

  1. 1. Department of Ophthalmology,  Nanjing Tongren Hospital, The Affiliated Hospital of Medical College of Southeast University, Nanjing 211100,  China; 2. Beijing Tongren Eye Center, Beijing Ophthalmology & Visual Sciences Key Laboratory, Beijing Tongren Hospital, Capital Medical University, Beijing 100730, China
  • Received:2013-06-25 Published:2013-08-16

Abstract:

Objective    To compare the features of corneal flaps created using the FS200 and Moria M2 microkeratome 90μm-knife. Methods    A pilot and prospective study was designed. Ninety eyes of 145 patients were enrolled in this clinical trial. The patients were divided into the FS200 group (50 eyes) and the M2 microkeratome 90μm-knife group (40 eyes), with matching demography. Fourier-domain optical coherence tomography (RTVue OCT) was used to measure flap thickness using 10 settings on the 90 corneas at one week post-operatively. The features of the LASIK flaps were analyzed on the basis of the outcomes. Written informed consent was obtained from each patient prior to LASIK. Results    The mean flap thickness of the FS200 group was considerably thinner than that of the Moria 90 group (112.2±3.2μm versus 128.2±11.2μm) (P<0.01). The corneal flaps in both the FS200 groups showed a flat shape and in the Moria 90 group showed a meniscus shape. The central flap thickness of the FS200 group was not evidently different from that of peripheral(P>0.05), but in the Moria 90 group, the central flap thickness was obviously thinner than the peripheral thickness (P<0.05). The mean deviation between the achieved and attempted flap thickness (110μm) was (2.99±4.34)μm in the FS200 group and (16.82±9.72)μm in the Moria 90 group (P<0.01).  Conclusion    The shape of flaps created using the FS200 is more uniform and closer to the expected thickness of 110μm than the ones created using the Moria M2 90 microkeratome.

Key words: Laser in situ keratomileusis, Fourierdomain optical coherence tomography, Flap thickness, femtosecond laser; Microkeratome

CLC Number: 

  • R779.63
[1] ZHANG Qiu-lu, WANG Yong-hua, LI Ying, WANG Yue, LIU Jing, HU Ya-bin, XU Wen, ZHENG Yan, LIU Qian, ZHAI Chang-bin. Evaluation of corneal flaps made by femtosecond laser Ziemer FEMTO LDV “Classic” and “Crystal Line LASIK” [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2014, 28(3): 75-79.
[2] SUN Li-wang, CHE Cheng-kai, SU Gang, LIU Guang-yuan. Effect of mitomycin C in treatment of epithelial ingrowth after LASIK [J]. J Otolaryngol Ophthalmol Shandong Univ, 2013, 27(4): 79-80.
[3] HAN Shi-chao1, CUI Chuan-bo2, LI Yan1, HAO Fa-xiang1, SHEN Hong-jing1, XIAO Jun-jie1. Comparison of corneal nerve regeneration of femtosecond laser and keratotome for laser in situ keratomileusis using confocal  microscope [J]. J Otolaryngol Ophthalmol Shandong Univ, 2013, 27(2): 71-74.
[4] ZHU Wei1, MU Guo-ying2. Effect of different depth of corneal flap on dry eye syndrome after corneal refractive operation [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2012, 26(5): 1-2.
[5] ZHAO Jing-jing1, YANG Xue-qiu1, ZHUANG Wen-juan2. Recent developments in assessing the effect of LASIK on the retina [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2012, 26(3): 79-82.
[6] LI Yan,WU Yu-wei,ZHANG Zuo-hong,LI Jing-hai . Comparison of laser in situ keratomileusis and laser epithelial
keratomileusis in treatment of hyperopia
[J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2008, 22(5): 460-463 .
[7] GAO Jian-lu,WEI Shu-fang,ZHENG Xiao-li . The wavefront-guided laser in situ keratomileusis(LASIK) in correcting low and midrange myopia [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2007, 21(6): 557-559 .
[8] LI Chun-lei,JIANG Bo,GAO Mu-jie,ZHONG Wen-dong,CAI Hui-zhao . Characteristics of excimer laser in situ keratomileusis for myopia in aged patients [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2006, 20(4): 361-363 .
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!