JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY) ›› 2017, Vol. 31 ›› Issue (4): 40-42.doi: 10.6040/j.issn.1673-3770.1.2017.023

Previous Articles     Next Articles

Diagnosis and treatment of reverse implantable collamer lens orientation: A case report.

LI Xi, LI Shuyi, XU Wen   

  1. Eye Center, the Second Affiliated Hospital, College of Medicine, Zhejiang University, Hangzhou 310009, Zhejiang, China
  • Received:2017-07-07 Online:2017-08-16 Published:2017-08-16

Abstract: The implantable collamer lens(ICL)is considered to be a safe and reversible technique used in intraocular refractive surgery. The ICL has a vaulted design to fit the space between the iris and lens. Occasionally, the ICL is implanted in the reverse anteroposterior orientation, but this may lead to an unsatisfactory refractive state and even severe complications. A patient with reverse ICL orientation was admitted to our department. The diagnostic process, treatment, and follow-up are reported.

Key words: Implantable collamer lens, Refractive error

CLC Number: 

  • R778
[1] Huang D, Schallhorn SC, Sugar A, et al. Phakic intraocular lens implantation for the correction of myopia: a report by the american academy of ophthalmology[J]. Ophthalmology, 2009, 116(11):2244-2258.
[2] Rosen E, Gore C. Staar collamer posterior chamber phakic intraocular lens to correct myopia and hyperopia[J]. J Cataract Refract Surg, 1998, 24(5):596-606.
[3] Sanders DR, Vukich JA, Doney K, et al. U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopia[J]. Ophthalmology, 2003, 110(2):255-266.
[4] Sanders DR, Doney K,Poco M. United States Food and Drug Administration clinical trial of the Implantable Collamer Lens(ICL)for moderate to high myopia: three-year follow-up[J]. Ophthalmology, 2004, 111(9):1683-9162.
[5] Sanders DR, Schneider D, Martin R, et al. Toric Implantable Collamer Lens for moderate to high myopic astigmatism[J]. Ophthalmology, 2007, 114(1):54-61.
[6] Liang GL, Wu J, Shi JT, et al. Implantable collamer lens versus iris-fixed phakic intraocular lens implantation to correct myopia: a meta-analysis[J]. PLoS One, 2014, 9(8):e104649.
[7] Goyal JL, Arora R, Manudhane A, et al. Diagnosis of reverse Implantable Collamer Lens(ICL)orientation on Anterior Segment Optical Coherence Tomography(ASOCT)[J]. Saudi J Ophthalmol, 2016, 30(1):81-82.
[1] SUN JiOverview,LI CanGuidance. Prediction and stability of axial intraocular lens position after cataract surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 7-12.
[2] LI YansongOverview,ZHU YuguangGuidance. Research progress on the effects of tear film stability on visual quality after phacoemulsification [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 19-25.
[3] WAN Bo, LI Donghui, LUO Yan, LI Ying. Lens vault changes and associated factors after implantation of implantable collamer lenses with central flow [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2020, 34(2): 36-41.
[4] WANG Xuanqi,CHEN XunReview,WANG XiaoyingGuidance. Research advances on vault and relevant factors after implantable collamer lens implantation [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2020, 34(2): 72-78.
[5] PIAO JunjieOverview,LI YingGuidance. Recent advances and clinical applications in excimer laser surface ablation surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2020, 34(2): 79-84.
[6] YUE Shali, DENG Yingping. Implantable collamer lens implantation for regression of refraction after radical keratotomy: case report [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2020, 34(2): 85-87.
[7] WANG Daoguang, LIU Dongmei, BI Hongsheng. A case of trifocal intraocular lens implantation in patients with over-long axial cataract [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2018, 32(6): 117-118.
[8] WANG Jing, LI Bin, ZHANG Hui. A case of aseptic endophthalmitis after YAG laser [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2018, 32(6): 119-120.
[9] GAO Xue, HAO Linlin, LIU Shaohua, ZHANG Han. Comparison of two intraocular lens measurement formulas for prediction of postoperative refraction accuracy in patients with angle closure glaucoma and cataract [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2018, 32(1): 68-71.
[10] XU Jingjing, GUO Haike. Analysis of the effects of implantable contact lens and femtosecond laser small incision lenticule extraction for high myopia on ocular surface. [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2017, 31(4): 18-20.
[11] LI Kai-jun, GAO Dong-hong, ZHANG Dong-song, JIANG Gui-fang, LU Hui, SHANG Hui-fang, WANG Quan. Topography-guided customized corneal ablation for complex refractive errors [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2012, 26(5): 5-5.
[12] DENG Zhifeng1, FAN Qingxia2, WU Qi1. Clinical effects of a network multimedia amblyopia training  system on refractive error amblyopia [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2011, 25(4): 81-.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!