Progress in the research of intraocular lens power calculation formulas

TAN Yan, LI Can   

  1. Department of Ophthalmology, the First Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory of Ophthalmology, Chongqing Institute of Ophthalmology, Chongqing 400016, China
  • Published:2019-12-23

Abstract: With the development of phacoemulsification surgery, the calculation of intraocular lens power has been paid greater attention. Various intraocular lens power formulas have been presented to optimize the visual quality after surgery. This paper comprehensively describes the progress in the research of various intraocular lens power formulas, such as the first-generation intraocular lens formula, the second-generation formula, Hill-RBF, Barrett True-K, and so on.

Key words: Intraocular lens formula, Cataract surgery, Calculation of lens power

CLC Number: 

  • R773.4
[1] Martinez-Enriquez E, Pérez-Merino P, Durán-Poveda S, et al. Estimation of intraocular lens position from full crystalline lens geometry: towards a new generation of intraocular lens power calculation formulas[J]. Sci Rep, 2018, 8(1): 9829. doi:10.1038/s41598-018-28272-6.
[2] Retzlaff JA, Sanders DR, Kraff MC. Development of the SRK/T intraocular lens implant power calculation formula[J]. J Cataract Refract Surg, 1990, 16(3): 333-340. doi:10.1016/s0886-3350(13)80705-5.
[3] Fyodorov SN, Galin MA, Linksz A. Calculation of the optical power of intraocular lenses[J]. Invest Ophthalmol, 1975, 14(8): 625-628.
[4] Sanders DR, Retzlaff J, Kraff MC. Comparison of the SRK II formula and other second generation formulas[J]. J Cataract Refract Surg, 1988, 14(2): 136-141. doi:10.1016/s0886-3350(88)80087-7.
[5] Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas[J]. J Cataract Refract Surg, 1993, 19(6): 700-712. doi:10.1016/s0886-3350(13)80338-0.
[6] Cooke DL, Cooke TL. Prediction accuracy of preinstalled formulas on 2 optical biometers[J]. J Cataract Refract Surg, 2016, 42(3): 358-362. doi:10.1016/j.jcrs.2015.11.040.
[7] Gökce SE, Zeiter JH, Weikert MP, et al. Intraocular lens power calculations in short eyes using 7 formulas[J]. J Cataract Refract Surg, 2017, 43(7): 892-897. doi:10.1016/j.jcrs.2017.07.004.
[8] Hoffer KJ, Savini G. IOL Power Calculation in Short and Long Eyes[J]. Asia Pac J Ophthalmol(Phila), 2017, 6(4): 330-331. doi:10.22608/APO.2017338.
[9] Chen C, Xu X, Miao YY, et al. Accuracy of intraocular lens power formulas involving 148 eyes with long axial lengths: A retrospective chart-review study[J]. J Ophthalmol, 2015, 2015: 976847. doi:10.1155/2015/976847.
[10] Hoffer KJ. Clinical results using the Holladay 2 intraocular lens power formula[J]. J Cataract Refract Surg, 2000, 26(8): 1233-1237. doi:10.1016/s0886-3350(00)00376-x.
[11] Terzi E, Wang L, Kohnen T. Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopia[J]. J Cataract Refract Surg, 2009, 35(7): 1181-1189. doi:10.1016/j.jcrs.2009.02.026.
[12] Roessler GF, Dietlein TS, Plange N, et al. Accuracy of intraocular lens power calculation using partial coherence interferometry in patients with high myopia[J]. Ophthalmic Physiol Opt, 2012, 32(3): 228-233. doi:10.1111/j.1475-1313.2012.00903.x.
[13] Bang S, Edell E, Yu QL, et al. Accuracy of intraocular lens calculations using the IOLMaster in eyes with long axial length and a comparison of various formulas[J]. Ophthalmology, 2011, 118(3): 503-506. doi:10.1016/j.ophtha.2010.07.008.
[14] Wang QW, Jiang W, Lin T, et al. Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta-analysis[J]. Clin Experiment Ophthalmol, 2018, 46(7): 738-749. doi:10.1111/ceo.13184.
[15] Roberts TV, Hodge C, Sutton G, et al. Comparison of Hill-radial basis function, Barrett Universal and current third generation formulas for the calculation of intraocular lens power during cataract surgery[J]. Clin Experiment Ophthalmol, 2018, 46(3): 240-246. doi:10.1111/ceo.13034.
[16] Kang BS, Han JM, Oh JY, et al. Intraocular lens power calculation after refractive surgery: a comparative analysis of accuracy and predictability[J]. Korean J Ophthalmol,2017,31(6):479-488. doi: 10.3341/ kjo. 2016.0078.
[1] TANG Wei, LI Yuanbin. New progress in refractive cataract surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2019, 33(2): 149-158.
[2] BI Hongsheng. Design of treatment protocol in refractive cataract surgery is important for postoperative visual outcomes. [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2017, 31(4): 1-4.
[3] SUN Hong-yi, ZHANG Han. Changes of macular thickness under optical coherent tomography in type 2 diabetic patients with cataract after phacoemulsification surgery and IOL implantation [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2014, 28(6): 72-76.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!