Journal of Otolaryngology and Ophthalmology of Shandong University ›› 2022, Vol. 36 ›› Issue (6): 13-18.doi: 10.6040/j.issn.1673-3770.0.2021.551
• 研究进展 • Previous Articles
HUANG ZiyanOverview,DUAN GuopingGuidance
CLC Number:
[1] Du W, Lou W, Wu Q. Personalized aspheric intraocular lens implantation based on corneal spherical aberration: a review[J]. Int J Ophthalmol, 2019, 12(11): 1788-1792. doi:10.18240/ijo.2019.11.19. [2] Hughes RP, Vincent SJ, Read SA, et al. Higher order aberrations, refractive error development and myopia control: a review[J]. Clin Exp Optom, 2020, 103(1): 68-85. doi:10.1111/cxo.12960. [3] 毕宏生. 精准屈光性白内障手术规划[J]. 山东大学耳鼻喉眼学报, 2017, 31(4): 1-4. doi: 10.6040/j.issn.1673-3770.1.2017.026. BI Hongsheng. Design of treatment protocol in refractive cataract surgery is important for postoperative visual outcomes[J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2017, 31(4): 1-4. doi: 10.6040/j.issn.1673-3770.1.2017.026. [4] 黄秀旗, 兰长骏, 廖萱, 等. 双通道视觉质量分析系统在球面和非球面人工晶状体眼视觉质量评价中的应用[J]. 眼科新进展, 2019, 39(10): 964-968. doi:10.13389/j.cnki.rao.2019.0220. HUANG Xiuqi, LAN Changjun, LIAO Xuan, et al. Evaluation of visual quality of spherical and aspheric intraocular lenses by dual channel optical quality analysis system[J]. Recent Advances in Ophthalmology, 2019, 39(10): 964-968. doi:10.13389/j.cnki.rao.2019.0220. [5] Chang DH, Rocha KM. Intraocular lens optics and aberrations[J]. Curr Opin Ophthalmol, 2016, 27(4): 298-303. doi:10.1097/ICU.0000000000000279. [6] 李史序, 王静, 赵江月, 等. 应用iTrace视觉功能分析仪测量双眼角膜像差的一致性[J]. 眼科新进展, 2019, 39(1): 63-67. doi:10.13389/j.cnki.rao.2019.0014. LI Shixu, WANG Jing, ZHAO Jiangyue, et al. Consistency analysis on the corneal aberration expressed by iTrace visual function analyzer[J]. Recent Advances in Ophthalmology, 2019, 39(1): 63-67. doi:10.13389/j.cnki.rao.2019.0014. [7] 任雁琳, 史春生, 姜波. FS-LASIK矫正不同程度近视术后角膜高阶像差的早期变化[J]. 国际眼科杂志, 2021, 21(5): 796-799. doi:10.3980/j.issn.1672-5123.2021.5.09. REN Yanlin, SHI Chunsheng, JIANG Bo. Early changes of the corneal higher-order aberrations after femtosecond laser-assisted in situ keratomileusis for different degrees of myopia[J]. International Eye Science, 2021, 21(5): 796-799. doi:10.3980/j.issn.1672-5123.2021.5.09. [8] 王飞, 卢奕, 蒋永祥, 等. 白内障超声乳化术切口对角膜高阶像差的影响[J]. 中国眼耳鼻喉科杂志, 2008, 8(3): 154-156. doi:10.3969/j.issn.1671-2420.2008.03.006. WANG Fei, LU Yi, JIANG Yongxiang, et al. Effects of small-incisions on corneal high-order aberrations after phacoemulsification[J]. Chinese Journal of Ophthalmology and Otorhinolaryngology, 2008, 8(3): 154-156. doi:10.3969/j.issn.1671-2420.2008.03.006. [9] Ruan XT, Liu ZZ, Luo LX, et al. The structure of the lens and its associations with the visual quality[J]. BMJ Open Ophthalmol, 2020, 5(1): e000459. doi:10.1136/bmjophth-2020-000459. [10] Li XJ, Wang Y, Dou R. Aberration compensation between anterior and posterior corneal surfaces after Small incision lenticule extraction and Femtosecond laser-assisted laser in situ keratomileusis[J]. Ophthalmic Physiol Opt, 2015, 35(5): 540-551. doi:10.1111/opo.12226. [11] Zhang M, Jing QH, Chen JH, et al. Analysis of corneal higher-order aberrations in cataract patients with high myopia[J]. J Cataract Refract Surg, 2018, 44(12): 1482-1490. doi:10.1016/j.jcrs.2018.07.048. [12] Oshika T, Klyce SD, Applegate RA, et al. Changes in corneal wavefront aberrations with aging[J]. Invest Ophthalmol Vis Sci, 1999, 40(7): 1351-1355. [13] Pérez-Gracia J, Varea A, Ares J, et al. Evaluation of the optical performance for aspheric intraocular lenses in relation with tilt and decenter errors[J]. PLoS One, 2020, 15(5): e0232546. doi:10.1371/journal.pone.0232546. [14] von Sonnleithner C, Bergholz R, Gonnermann J, et al. Clinical results and higher-order aberrations after 1.4-mm biaxial cataract surgery and implantation of a new aspheric intraocular lens[J]. Ophthalmic Res, 2015, 53(1): 8-14. doi:10.1159/000364808. [15] Tan QQ, Lin J, Tian J, et al. Objective optical quality in eyes with customized selection of aspheric intraocular lens implantation[J]. BMC Ophthalmol, 2019, 19(1): 152. doi:10.1186/s12886-019-1162-6. [16] 刘彧琦, 王静, 张劲松. 非恒定像差非球面人工晶状体的研究现状与进展[J]. 国际眼科杂志, 2019, 19(2): 248-251. doi:10.3980/j.issn.1672-5123.2019.2.14. LIU Yuqi, WANG Jing, ZHANG Jinsong. Research status and progress of non-constant aberration aspherical IOL[J]. International Eye Science, 2019, 19(2): 248-251. doi:10.3980/j.issn.1672-5123.2019.2.14. [17] Steinwender G, Strini S, Glatz W, et al. Depth of focus after implantation of spherical or aspheric intraocular lenses in hyperopic and emmetropic patients[J]. J Cataract Refract Surg, 2017, 43(11): 1413-1419. doi:10.1016/j.jcrs.2017.08.012. [18] 蔡芳菲, 郑广瑛, 王华君, 等. 角膜Q值引导下个体化人工晶状体植入术后视觉质量的临床观察[J]. 中华眼科杂志, 2017, 53(11): 814-820. doi:10.3760/cma.j.issn.0412-4081.2017.11.004. CAI Fangfei, ZHENG Guangying, WANG Huajun, et al. Clinical observation of visual quality after the individual implantation of intraocular lens guided by corneal Q value[J]. Chinese Journal of Ophthalmology, 2017, 53(11): 814-820. doi:10.3760/cma.j.issn.0412-4081.2017.11.004. [19] Poyales F, Garzón N, Rico L, et al. Comparison of visual performance between two aspheric monofocal intraocular lens models[J]. Clin Exp Optom, 2021: 1-7. doi:10.1080/08164622.2021.2009737. [20] Ferreira TB, Almeida A. Comparison of the visual outcomes and OPD-scan results of AMO tecnis toric and alcon acrysof IQ toric intraocular lenses[J]. J Refract Surg, 2012, 28(8): 551-556. doi:10.3928/1081597x-20120703-03. [21] Montés-Micó R, Ferrer-Blasco T, Cervño A. Analysis of the possible benefits of aspheric intraocular lenses: review of the literature[J]. J Cataract Refract Surg, 2009, 35(1): 172-181. doi:10.1016/j.jcrs.2008.09.017. [22] Pérez-Vives C, Ferrer-Blasco T, García-Lázaro S, et al. Optical quality comparison between spherical and aspheric toric intraocular lenses[J]. Eur J Ophthalmol, 2014, 24(5): 699-706. doi:10.5301/ejo.5000440. [23] Eom Y, Yoo E, Kang SY, et al. Change in efficiency of aspheric intraocular lenses based on pupil diameter.[J]. American Journal of Ophthalmology, 2013, 155(3):492-498. doi:10.1016/j.ajo.2012.09.024. [24] Yamaguchi T, Negishi K, Ono T, et al. Feasibility of spherical aberration correction with aspheric intraocular lenses in cataract surgery based on individual pupil diameter[J]. J Cataract Refract Surg, 2009, 35(10):1725-1733. doi:10.1016/j.jcrs.2009.05.031. [25] Miháltz K, Vécsei-Marlovits PV. The impact of visual axis position on the optical quality after implantation of multifocal intraocular lenses with different asphericity values[J]. Graefes Arch Clin Exp Ophthalmol, 2021, 259(3): 673-683. doi:10.1007/s00417-020-05052-5. [26] Ashena Z, Maqsood S, Ahmed SN, et al. Effect of intraocular lens tilt and decentration on visual acuity, Dysphotopsia and wavefront aberrations[J]. Vision(Basel), 2020, 4(3): 41. doi:10.3390/vision4030041. [27] 单玉琴, 郑广瑛, 李莉, 等. 区域折射型多焦点人工晶状体植入术与单焦点人工晶状体植入术中长期视觉质量比较[J]. 中华实验眼科杂志, 2020, 38(4): 348-354. doi:10.3760/cma.j.cn115985-20190902-00379. SHAN Yuqin, ZHENG Guangying, LI Li, et al. Comparison of medium and long term visual quality between regional refractive multifocal intraocular lens implantation and unifocal intraocular lens implantation[J]. Chinese Journal of Experimental Ophthalmology, 2020, 38(4): 348-354. doi:10.3760/cma.j.cn115985-20190902-00379. [28] 王文莹, 王军, 张晶, 等. 多焦点与单焦点非球面人工晶状体植入后视觉质量的临床观察[J]. 中华眼科杂志, 2010, 46(8): 686-690. doi:10.3760/cma.j.issn.0412-4081.2010.08.004. WANG Wenying, WANG Jun, ZHANG Jing, et al. Clinical observation on visual quality in patients implanted with monofocal and multifocal aspheric intraocular lenses[J]. Chinese Journal of Ophthalmology, 2010, 46(8): 686-690. doi:10.3760/cma.j.issn.0412-4081.2010.08.004. [29] Liao X, Lin J, Tian J, et al. Evaluation of optical quality: ocular scattering and aberrations in eyes implanted with diffractive multifocal or monofocal intraocular lenses[J]. Curr Eye Res, 2018, 43(6): 696-701. doi:10.1080/02713683.2018.1449220. [30] Peng C, Zhao JY, Ma LW, et al. Optical performance after bilateral implantation of apodized aspheric diffractive multifocal intraocular lenses with +3.00-D addition power[J]. Acta Ophthalmol, 2012, 90(8): e586-e593. doi:10.1111/j.1755-3768.2012.02497.x. [31] 计菁, 罗敏, 范先群, 等. 衍射型多焦点人工晶体与单焦点人工晶体植入术后的临床观察[J]. 上海交通大学学报(医学版), 2011, 31(8): 1073-1077. doi:10.3969/j.issn.1674-8115.2011.08.005. JI Jing, LUO Min, FAN Xianqun, et al. Clinical observations of monofocal intraocular lens and multifocal intraocular lens implantation in cataract surgery[J]. Journal of Shanghai Jiao Tong University(Medical Science), 2011, 31(8): 1073-1077. doi:10.3969/j.issn.1674-8115.2011.08.005. [32] Wang SY, Stem MS, Oren G, et al. Patient-centered and visual quality outcomes of premium cataract surgery: a systematic review[J]. Eur J Ophthalmol, 2017, 27(4): 387-401. doi:10.5301/ejo.5000978. [33] Liu XM, Xie LX, Huang YS. Effects of decentration and tilt at different orientations on the optical performance of a rotationally asymmetric multifocal intraocular lens[J]. J Cataract Refract Surg, 2019, 45(4): 507-514. doi:10.1016/j.jcrs.2018.10.045. [34] Pilger D, Homburg D, Brockmann T, et al. Clinical outcome and higher order aberrations after bilateral implantation of an extended depth of focus intraocular lens[J]. Eur J Ophthalmol, 2018, 28(4): 425-432. doi:10.1177/1120672118766809. [35] Yeu E, Cuozzo S. Matching the patient to the intraocular lens: preoperative considerations to optimize surgical outcomes[J]. Ophthalmology, 2021, 128(11): e132-e141. doi:10.1016/j.ophtha.2020.08.025. [36] 魏佩佩. 多焦点人工晶体植入术后的视觉质量及并发症[J]. 山东大学耳鼻喉眼学报, 2021, 35(2): 141-146. doi:10.6040/j.issn.1673-3770.0.2020.164. WEI Peipei. Visual quality and complications after implantation of multifocal intraocular lens[J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(2): 141-146. doi:10.6040/j.issn.1673-3770.0.2020.164. [37] He WW, Qiu XD, Zhang SH, et al. Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan Ⅲ aberrometer[J]. Eye(Lond), 2018, 32(7): 1237-1243. doi:10.1038/s41433-018-0068-5. [38] Shin E, Yoo YS, Choi SH, et al. Clinical outcomes of topography-guided femtosecond laser-assisted in situ keratomileusis after multifocal intraocular lens implantation[J]. Sci Rep, 2020, 10(1): 10666. doi:10.1038/s41598-020-67726-8. [39] Zhong YY, Zhu YN, Wang W, et al. Femtosecond laser-assisted cataract surgery versus conventional phacoemulsification: comparison of internal aberrations and visual quality[J]. Graefe's Arch Clin Exp Ophthalmol, 2022, 260(3): 901-911. doi:10.1007/s00417-021-05441-4. |
[1] | DUAN Lian, MENG FanlanReview,DANG GuangfuGuidance. Effect of dry eye on refractive cataract surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 1-6. |
[2] | SUN JiOverview,LI CanGuidance. Prediction and stability of axial intraocular lens position after cataract surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 7-12. |
[3] | HU Zunxia, SIMA Jing, QIN Bo, CAO Jiaguo, PAN Wei. Comparative study on the use of contact lens in Nd: YAG laser posterior capsulotomy [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(5): 41-45. |
[4] | DAI ChengOverview,LI BinzhongGuidance. Advances in multifocal soft corneal contact lens research [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(5): 100-105. |
[5] | YANG Ru, ZHANG Yuguang, XU Xianghui, WU Xuelian, TAO Yuan, TAN Yue. A clinical study on the effect of phacoemulsification on the retinal structure in the macular region of senile cataract [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(4): 97-102. |
[6] | LI Jing, ZHANG Hui, WANG Jing. A clinical study on the effect of using different intraocular lens implants on visual quality [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(2): 90-95. |
[7] | PENG Jiao, ZHONG Dingjuan, CHEN Jiao, ZUO Jun, WANG Hua. The effect of the relationship between the diameter of the optical zone and the diameter of the dark pupil on the visual quality of patients with different degrees of myopia after SMILE [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(2): 100-107. |
[8] | LI Bin, FANG Xuejun, WU De, HUANG Min. Agreement study of implantable collamer lens based on NK and KS formulas in the early stage after surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(6): 33-41. |
[9] | HAI Yue,LIAO Xuan. Research progress and clinical application of Catquest-9SF [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(6): 142-146. |
[10] | WANG Shushu, FU Yahui, YU Ruoyu, HOU Yi, YANG Jiguo. The law of medication for the treatment of endogenous eye disease in chinese medical code based on data mining [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(4): 81-87. |
[11] | FU Yihao, XU Yixuan,YAN Hong, ZHANG Jie. Recent research advances in the role of glutaredoxin in oculopathy [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(3): 125-130. |
[12] | WEI Peipei,LI Can. Visual quality and complications after implantation of multifocal intraocular lens [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(2): 141-146. |
[13] | To explore the best method for diagnosis and treatments of post-surgical posterior ischemic optic neuropathy(PION). MethodsReview the medical records of a 78-year-old female patient who presented with sudden vision loss in her right eye on the fourth day after phacoemulsification and implantation of a posterior chamber intraocular lens in other hospital. After the electrophysiological examination and fundus fluorescein angiography, the patient was diagnosed as posterior ischemic optic neuropathy after cataract surgery in his right eye. She was administered with a retrobulbar injection of Anisodamine and placed on steroid pulse therapy. ResultsOn the 19th day after treatment, her visual acuity had recovered to 0.05. ConclusionThis is a rare case, and since post-surgical posterior ischemic optic neuropathy(PION)has no definite and effective treatment yet, active vigilance should be maintained before surgery. Detailed systemic history and physical examination are important for patients with high risks of developing PION, especially for evaluating their systemic hemodynamics. To sum up, PION should be considered in patients who have sudden severe vision loss and/or visual field defects with no obvious changes in the fundus after excluding other optic nerve diseases.. Posterior ischemic optic neuropathy after cataract surgery: a case report and literature reviewWANG Zongyi, QU Jinfeng Department of Ophthalmology, Peking University Peoples Hospital, Beijing 100044, ChinaAbstract:Objective〓 [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2020, 34(4): 56-59. |
[14] | LI Ying, JIANG Yang. A discussion on the choice of surgical methods for correction of myopia [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2020, 34(2): 1-6. |
[15] | ZHANG Fengju, LI Yu. Key criteria for screening before corneal refractive surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2020, 34(2): 7-12. |
|