正常气骨导听性脑干反应及其应用

杨长亮1,黄治物2,姚行齐1,诸勇1,孙艺1   

  1. 1. 广州军区武汉总医院耳鼻咽喉科,湖北 武汉 430070;2. 武汉大学人民医院听力中心,湖北 武汉 430060
  • 收稿日期:1900-01-01 修回日期:1900-01-01 出版日期:2006-02-25 发布日期:2006-02-25

Study on auditory brainstem response

YANG Changliang1, HUANG Zhiwu2, YAO Hangqi1, ZHU Yong1, SNU Yi1   

  1. 1. Department of Otolaryngology, Wuhan General Hospital of PLA, Wuhan 430070, Hubei, China;2. Auditory Center, Renmin Hospital of Wuhan University, Wuhan 430060, Hubei, China
  • Received:1900-01-01 Revised:1900-01-01 Online:2006-02-25 Published:2006-02-25

摘要: [摘要]目的:研究骨导听性脑干反应(ABR)的波形特点及正常的气、骨导ABR Ⅴ波潜伏期-强度曲线及相应的反应阈值,为临床气导ABR(ACABR)和骨导ABR(BCABR)的联合应用提供参考依据。方法:利用Nicoletspirit型诱发电位仪、EAR3A插入式耳机和Radioear B71骨振动器对一组听力正常年轻人(男32耳、女24耳)进行短声气骨导ABR测试,并观察对侧给予白噪声掩蔽对BCABR阈值及潜伏期的影响。结果:气骨导ABR相应强度下波形相似波Ⅴ潜伏期-强度曲线表明,随着刺激强度逐渐减低,潜伏期逐渐延长。骨导Click的潜伏期要比气导Click潜伏期延长的程度大,BCABR反应阈比气导ABR高。对侧70?dBSPL以下强度宽带噪声的使用对BCABR阈值及阈上10?dB强度下波Ⅴ潜伏期均无显著影响(P>0.05)。结论:(1) BCABR波形特点与相应刺激强度的ACABR极为相似。BCABR与ACABR潜伏期-强度函数曲线可望联合用于传导障碍及其程度的评估;(2) 骨导行为的听阈水平超过40?dBHL时,BCABR难以引出,对其结果的解释应持慎重态度;(3) 骨导ABR测试时常规加对侧噪声掩蔽,但掩蔽声强度不应超过60?dB。

关键词: 听性脑干诱发反应, 知觉掩蔽, 骨振器

Abstract: [ABSTRACT]Objective: To observe normative auditory brainstem response (ABR) latencyintensity functions and the threshold and provide reference for combined clinical use of air and boneconducted ABR. Methods: ABR absolute thresholds and latencies(Ⅴwaves)were obtained from 56 ears of 28 young persons with normal hearing using both the EARTONE insert earphone and the Radioear B71 bone viboratory. Results: The air and boneconducted waveⅤlatencyintensity functions exhibited increased latencies as intensity decreased. The boneconducted clicks yielded somewhat longer latencies than the airconducted ones. Conclusions: (1) The waves of air and boneconducted ABR are similar, and more information on ascertaining the presence and magnitude of a conductive hearing loss can be obtained when both air and boneconducted ABR wave V latencyintensity functions are administered. (2) When the threshold of boneconducted hearing exceeds approximately to 40 dBHL, no BCABR responses can be observed. (3) Masking is often necessary when administering boneconducted ABR test, but intensity of masking should not exceed to over 60 dBSPL.

Key words: Perceptual masking, Bone viborator , Auditory brain stem evoked response