摘要:

目的   通过对解剖学、影像学、神经导航三种测量方式精确度的对比,对数字化颅底外科手术的可行性进行量化评估。方法   取颅底标本25个,对前半规管-卵圆孔之间的距离(50侧),分别进行游标卡尺测量(解剖学测量)、影像学测量及神经导航测量。所得数据进行记录,并采用SPSS 19.0软件进行统计分析,比较三种测量方式各自的精确度。结果   ①解剖学测量的平均偏差(离均差平均值)>影像学测量数据与解剖学测量均数的平均偏差(P<0.01); ②神经导航测量的与解剖学测量均数的平均偏差>影像学测量与解剖学测量均数的平均偏差(P<0.01); ③神经导航测量的与解剖学测量均数的平均偏差略>解剖学测量的平均偏差, 但P(90%)>0.8。结论   ①影像学测量数据在评估个体解剖学特征方面的精密度,高于基于群体的解剖学测量数据;②神经导航系统在注册及应用中会出现一些偏差,影响神经导航系统的精确性;③即使不可避免地存在着误差,从统计学角度来看,神经导航测量依然无可否认地可视为与解剖学测量为等效(把握度高达90%)。

关键词: 神经导航, 颅底外科, 测量方式

Abstract:

Objective   To quantitatively evaluated the feasibility of digitalized skull base surgery by comparing the corresponding accuracy of anatomical, imageology and neuronavigator based measurements. Methods   Distance between the anterior semicircular canal and the oval foramen of 25 cadaver skull bases (50 sides) were measured with caliper (an anatomical measurement), CT (an imageology base measurement) and neuronavigator (a neuronavigator based measurement), respectively. The data were documented and the accuracy of three different methods of measurement was statistically analyzed with Spss19.0 software. Results   ① The mean deviation of anatomical measurement was larger than that of the imageology based measurement from the corresponding mean of anatomical measurement(P<0.01); ② The mean deviation of the neuronavigator based measurement was larger than that of the imageology based measurement from the mean of anatomical measurement (P<0.01); ③ The mean deviation of the neuronavigator based measurement from the mean of anatomical measurement was a little bit larger than that of the anatomical measurement, whereas the P value (90%) was larger than 0.8. Conclusion   ① The data from imageology based measurement are more accurate than those from group-based anatomical measurement in evaluating individual anatomical characteristics; ② Errors occurred during registration and application will compromise the accuracy of a neuronavigator to a more or less extent; ③ Statistically equivalent accuracy is undeniable(the power of the test was as high as 90%)between the anatomical and neuronavigator based measurements, even if deviations from the latter are inevitable.

Key words: Neuronavigator; Skull base surgery, Measurement

中图分类号: 

  • R651
[1] 张斌, 李峰, 张良文, 杨扬, 朱树干. 颅脑外伤后顽固性脑脊液耳漏的手术策略和技巧研究[J]. 山东大学耳鼻喉眼学报, 2015, 29(6): 17-21.
[2] 周鹏1,李培华1,刘稳1,许学谷1,康海全2. 气管切开术后肺部感染的病原学分析及防治[J]. 山东大学耳鼻喉眼学报, 2012, 26(2): 66-68.
[3] 马兆鑫1,李明2,曹奕2,陈旭辉2. 乙状窦后锁孔手术治疗三叉神经痛、半面痉挛和舌咽神经痛[J]. 山东大学耳鼻喉眼学报, 2011, 25(5): 23-.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!