Journal of Otolaryngology and Ophthalmology of Shandong University ›› 2026, Vol. 40 ›› Issue (2): 74-79.doi: 10.6040/j.issn.1673-3770.0.2024.597
• Original Article • Previous Articles Next Articles
WANG Xinmeng1, JI Junya2, YU Haonan3, FU Hongchen1, WANG Xiang1, ZHENG Zekun1, LI Yan1, ZHONG Yingying1
CLC Number:
| [1] 王宁利, 王怀洲. 新型微创抗青光眼手术推广过程中应严格掌握适应证[J]. 中华眼科杂志, 2021, 57(9)641-643. doi: 10.3760/cma.j.cn112142-20210719-00341 WANG Lixin, WANG Huaizhou. Strictly following the indications during the promotion of micro-invasive glaucoma surgeries[J]. Chinese Journal of Ophthalmology, 2021 57(9)641-643. doi: 10.3760/cma.j.cn112142-20210719-00341 [2] Panse K, Le C, Hubbell M, et al. Surgical outcomes of phacoemulsification/goniosynechialysis with and without endocyclophotocoagulation in patients with chronic angle closure glaucoma[J]. Indian J Ophthalmol, 2019, 67(3): 366-370. doi: 10.4103/ijo.IJO_895_18 [3] Razeghinejad MR, Myers JS. Contemporary approach to the diagnosis and management of primary angle-closure disease[J]. Surv Ophthalmol, 2018, 63(6): 754-768. doi: 10.1016/j.survophthal.2018.05.001 [4] Kang SY, Hong SM, Won JB, et al. Inaccuracy of intraocular lens power prediction for cataract surgery in angle-closure glaucoma[J]. Yonsei Med J, 2009, 50(2): 206-210. doi: 10.3349/ymj.2009.50.2.206 [5] Khoramnia R, Auffarth G, Łabuz G, et al. Refractive outcomes after cataract surgery[J]. Diagnostics(Basel), 2022, 12(2): 243. doi: 10.3390/diagnostics12020243 [6] Hoffer KJ, Aramberri J, Haigis W, et al. Protocols for studies of intraocular lens formula accuracy[J]. Am J Ophthalmol, 2015, 160(3): 403-405.e1. doi: 10.1016/j.ajo.2015.05.029 [7] Stopyra W, Voytsekhivskyy O, Grzybowski A. Accuracy of 20 intraocular lens power calculation formulas in medium-long eyes[J]. Ophthalmol Ther, 2024, 13(7): 1893-1907. doi: 10.1007/s40123-024-00954-7 [8] 高雪, 郝琳琳, 刘少华, 等. 两种人工晶体计算公式预测闭角型青光眼合并白内障患者超声乳化手术后屈光度准确性的比较[J]. 山东大学耳鼻喉眼学报, 2018, 32(1): 68-71. doi: 10.6040/j.issn.1673-3770.0.2017.512 GAO Xue, HAO Linlin, LIU Shaohua, et al. Comparison of two intraocular lens measurement formulas for prediction of postoperative refraction accuracy in patients with angle closure glaucoma and cataract[J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2018, 32(1): 68-71. doi: 10.6040/j.issn.1673-3770.0.2017.512 [9] Gökce SE, Zeiter JH, Weikert MP, et al. Intraocular lens power calculations in short eyes using 7 formulas[J]. J Cataract Refract Surg, 2017, 43(7): 892-897. doi: 10.1016/j.jcrs.2017.07.004 [10] Pereira A, Popovic MM, Ahmed Y, et al. A comparative analysis of 12 intraocular lens power formulas[J]. Int Ophthalmol, 2021, 41(12): 4137-4150. doi: 10.1007/s10792-021-01966-z [11] Darcy K, Gunn D, Tavassoli S, et al. Assessment of the accuracy of new and updated intraocular lens power calculation formulas in 10 930 eyes from the UK National Health Service[J]. J Cataract Refract Surg, 2020, 46(1): 2-7. doi: 10.1016/j.jcrs.2019.08.014 [12] Connell BJ, Kane JX. Comparison of the Kane formula with existing formulas for intraocular lens power selection[J]. BMJ Open Ophthalmol, 2019, 4(1): e000251. doi: 10.1136/bmjophth-2018-000251 [13] Savini G, Di Maita M, Hoffer KJ, et al. Comparison of 13 formulas for IOL power calculation with measurements from partial coherence interferometry[J]. Br J Ophthalmol, 2021, 105(4): 484-489. doi: 10.1136/bjophthalmol-2020-316193 [14] Melles RB, Holladay JT, Chang WJ. Accuracy of intraocular lens calculation formulas[J]. Ophthalmology, 2018, 125(2): 169-178. doi: 10.1016/j.ophtha.2017.08.027 [15] Eom Y, Kang SY, Song JS, et al. Comparison of Hoffer Q and Haigis formulae for intraocular lens power calculation according to the anterior chamber depth in short eyes[J]. Am J Ophthalmol, 2014, 157(4): 818-824.e2. doi: 10.1016/j.ajo.2013.12.017 [16] Wang QW, Jiang W, Lin T, et al. Meta-analysis of accuracy of intraocular lens power calculation formulas in short eyes[J]. Clin Exp Ophthalmol, 2018, 46(4): 356-363. doi: 10.1111/ceo.13058 [17] Kim JW, Eom Y, Yoon EG, et al. Algorithmic intraocular lens power calculation formula selection by keratometry, anterior chamber depth and axial length[J]. Acta Ophthalmol, 2022, 100(3): e701-e709. doi: 10.1111/aos.14956 [18] Lu WH, Hou Y, Yang HF, et al. A systemic review and network meta-analysis of accuracy of intraocular lens power calculation formulas in primary angle-closure conditions[J]. PLoS One, 2022, 17(10): e0276286. doi: 10.1371/journal.pone.0276286 [19] Lin YD, Yin YL, Huang CK, et al. Accuracy of new intraocular lens calculation formulas in primary angle closure glaucoma patients who underwent phacoemulsification combined with goniosynechialysis[J]. Int Ophthalmol, 2024, 45(1): 2. doi: 10.1007/s10792-024-03367-4 [20] Hou M, Ding YJ, Liu LP, et al. Accuracy of intraocular lens power calculation in primary angle-closure disease: comparison of 7 formulas[J]. Graefes Arch Clin Exp Ophthalmol, 2021, 259(12): 3739-3747. doi: 10.1007/s00417-021-05295-w [21] Day AC, Cooper D, Burr J, et al. Clear lens extraction for the management of primary angle closure glaucoma: surgical technique and refractive outcomes in the EAGLE cohort[J]. Br J Ophthalmol, 2018, 102(12): 1658-1662. doi: 10.1136/bjophthalmol-2017-311447 [22] Kim NH, Gim Y, Choi KR, et al. Comparison of intraocular lens power calculation formulas in patients with a history of acute primary angle-closure attack[J]. BMC Ophthalmol, 2023, 23(1): 482. doi: 10.1186/s12886-023-03232-5 [23] Omoto MK, Torii H, Hayashi K, et al. Ratio of axial length to corneal radius in Japanese patients and accuracy of intraocular lens power calculation based on biometric data[J]. Am J Ophthalmol, 2020, 218: 320-329. doi: 10.1016/j.ajo.2020.03.006 [24] Nishide T, Hayakawa N, Kimura I, et al. Postoperative refractive error following cataract surgery after the first attack of acute primary angle closure[J]. Int Ophthalmol, 2014, 34(4): 805-808. doi: 10.1007/s10792-013-9878-4 [25] Guyton DL, Uozato H, Wisnicki HJ. Rapid determination of intraocular lens tilt and decentration through the undilated pupil[J]. Ophthalmology, 1990, 97(10): 1259-1264. doi: 10.1016/s0161-6420(90)32422-3 [26] Korynta J, Bok J, Cendelin J. Changes in refraction induced by change in intraocular lens position[J]. J Refract Corneal Surg, 1994, 10(5): 556-564. [27] Joo J, Whang WJ, Oh TH, et al. Accuracy of intraocular lens power calculation formulas in primary angle closure glaucoma[J]. Korean J Ophthalmol, 2011, 25(6): 375-379. doi: 10.3341/kjo.2011.25.6.375 [28] Jeong J, Song H, Lee JK, et al. The effect of ocular biometric factors on the accuracy of various IOL power calculation formulas[J]. BMC Ophthalmol, 2017, 17(1): 62. doi: 10.1186/s12886-017-0454-y [29] 邓水凤, 庞柏林, 廖锐, 等. 原发性急性闭角型青光眼合并白内障超乳术后的屈光误差及其相关影响因素[J]. 国际眼科杂志, 2018, 18(8): 1488-1491. doi: 10.3980/j.issn.1672-5123.2018.8.32 DENG Shuifeng, PANG Bolin, LIAO Rui, et al. Analysis of the refraction error and the influencing factors after phacoemulsification in acute primary angle-closure glaucoma with cataract[J]. International Eye Science, 2018, 18(8): 1488-1491. doi: 10.3980/j.issn.1672-5123.2018.8.32 [30] Ning XN, Yang YH, Yan H, et al. Anterior chamber depth-a predictor of refractive outcomes after age-related cataract surgery[J]. BMC Ophthalmol, 2019, 19(1): 134. doi: 10.1186/s12886-019-1144-8 [31] Lee TE, Yoo C, Kim YY. The effects of peripheral anterior synechiae on refractive outcomes after cataract surgery in eyes with primary angle-closure disease[J]. Medicine(Baltimore), 2021, 100(14): e24673. doi: 10.1097/MD.0000000000024673 [32] Suzuki T, Ueta Y, Tachi N, et al. Refractive outcomes after immediate primary phacoemulsification for acute primary angle closure[J]. Sci Rep, 2023, 13(1): 13283. doi: 10.1038/s41598-023-40585-9 [33] Hata M, Hirose F, Oishi A, et al. Changes in choroidal thickness and optical axial length accompanying intraocular pressure increase[J]. Jpn J Ophthalmol, 2012, 56(6): 564-568. doi: 10.1007/s10384-012-0173-0 [34] Leydolt C, Findl O, Drexler W. Effects of change in intraocular pressure on axial eye length and lens position[J]. Eye, 2007, 22(5): 657-661. doi: 10.1038/sj.eye.6702709 |
| [1] | LIU Zhen, ZHOU Weiwei, LIU Hanjing, ZHANG Yi, ZHU Yuguang, ZHU Yan. Influence of Alpha angle of intraocular lens on visual quality after the implantation of extended depth-of-field intraocular lens [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2026, 40(1): 47-53. |
| [2] | HUANG Qi, DENG Xuwen, WANG Peipei, CHEN Yequn, GU Xuejun. Research on evaluating the cataract surgery level of ophthalmologists using eyeSi surgical simulator [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2025, 39(5): 83-88. |
| [3] | WANG Sheng, HUANG Xudong. Recent advancements in the research on ferroptosis and age-related cataracts [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2025, 39(5): 161-168. |
| [4] | SUN Hongxiang, CAO Juan. Status of mental fragility in elderly cataract patients and its correlation with hope level and alexithymia [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2025, 39(1): 89-95. |
| [5] | MA Jiling, WANG Xiaoming, LI Yan, MU Yanxiao, JIN Lin, KONG Hui, YANG Naifu, DANG Guangfu. Evaluation of three different aspheric intraocular lens tilts and decentrations in capsular bags after cataract surgery based on CASIA2 [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2024, 38(4): 76-85. |
| [6] | YUSUFU·Maierhaba, ABULA·Kelimujiang, DING Lin, QIN Yanli, CHEN Xueyi. Fundus changes in high myopia cataract with posterior scleral staphyloma [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2023, 37(5): 107-114. |
| [7] | LI Wanyu, GU Xuejun. Anti-neutrophil cytoplasmic antibody associated vasculitis complicated with scleritis and cataract: a case study and literature review [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2023, 37(4): 149-152. |
| [8] | HAN Yiping, ZHANG Han. Research progress on the pathogenesis of posterior capsular opacification and on anterior capsular polishing [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2023, 37(4): 181-186. |
| [9] | ZHANG Yi, TANG Li. Oculocerebrorenal syndrome of lowe with glaucoma: a case report [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2023, 37(3): 93-97. |
| [10] | DONG Shuguang, GUO Fengfei, MENG Xuxia, YAN Shilong. Retrospective analysis of the causes of anterior capsular tear in early femtosecond laser-assisted cataract surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2023, 37(1): 110-114. |
| [11] | DUAN Lian, MENG FanlanReview,DANG GuangfuGuidance. Effect of dry eye on refractive cataract surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 1-6. |
| [12] | SUN JiOverview,LI CanGuidance. Prediction and stability of axial intraocular lens position after cataract surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 7-12. |
| [13] | HUANG ZiyanOverview,DUAN GuopingGuidance. Effect of higher-order aberrations on visual quality after cataract intraocular lens implantation [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 13-18. |
| [14] | LI YansongOverview,ZHU YuguangGuidance. Research progress on the effects of tear film stability on visual quality after phacoemulsification [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 19-25. |
| [15] | HUANG ZiyanOverview,DUAN GuopingGuidance. Effects of tilt and decentration on visual quality after various intraocular lens implantations [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 26-31. |
|