Journal of Otolaryngology and Ophthalmology of Shandong University ›› 2022, Vol. 36 ›› Issue (6): 26-31.doi: 10.6040/j.issn.1673-3770.0.2021.544

• 研究进展 • Previous Articles    

Effects of tilt and decentration on visual quality after various intraocular lens implantations

HUANG ZiyanOverview,DUAN GuopingGuidance   

  1. Department of Ophthalmology, the First Affiliated Hospital of Hunan Normal University/ People's Hospital of Hunan Province, Changsha 410000, Hunan, China
  • Published:2022-12-07

Abstract: Cataract phacoemulsification and intraocular lens(IOL)implantation are currently recognized as effective treatments for cataracts. The goal of cataract surgery has changed to refractive surgery to achieve good visual quality. Postsurgical IOL decentration and tilt can increase high-order aberrations and reduce visual quality. Different IOL have diverse effects on visual quality caused by postoperative decentration and tilt due to their design and other factors. Compared to the visual quality of other types of IOL, those of aspheric and multifocal IOLs are more susceptible to decentration and tilt. This paper reviews the relevant recent literature on tilt and decentration after IOL implantation, analyzes the cause and effect of the visual quality differences between various IOLs, and highlights additional treatment options and research directions to improve the prognosis of cataract patients.

Key words: Cataract, Intraocular lens, Tilt, Decentration, Visual quality

CLC Number: 

  • R776.1
[1] Nishi Y, Hirnschall N, Crnej A, et al. Reproducibility of intraocular lens decentration and tilt measurement using a clinical Purkinje meter[J]. J Cataract Refract Surg, 2010, 36(9): 1529-1535. doi:10.1016/j.jcrs.2010.03.043.
[2] Kimura S, Morizane Y, Shiode Y, et al. Assessment of tilt and decentration of crystalline lens and intraocular lens relative to the corneal topographic axis using anterior segment optical coherence tomography[J]. PLoS One, 2017, 12(9): e0184066. doi:10.1371/journal.pone.0184066.
[3] Sato T, Shibata S, Yoshida M, et al. Short-term dynamics after single- and three-piece acrylic intraocular lens implantation: a swept-source anterior segment optical coherence tomography study[J]. Sci Rep, 2018, 8(1): 10230. doi:10.1038/s41598-018-28609-1.
[4] 曾国燕, 张远平, 李静华, 等. 不同球差非球面人工晶状体个体化选择的研究进展[J]. 国际眼科杂志, 2017, 17(1): 62-65. doi:10.3980/j.issn.1672-5123.2017.1.15. ZENG Guoyan, ZHANG Yuanping, LI Jinghua, et al. Research advance of individual choice for different spherical aberration aspheric intraocular lens[J]. International Eye Science, 2017, 17(1): 62-65. doi:10.3980/j.issn.1672-5123.2017.1.15.
[5] Hirnschall N, Buehren T, Bajramovic F, et al. Prediction of postoperative intraocular lens tilt using swept-source optical coherence tomography[J]. J Cataract Refract Surg, 2017, 43(6): 732-736. doi:10.1016/j.jcrs.2017.01.026.
[6] Wang L, Guimaraes de Souza R, Weikert MP, et al. Evaluation of crystalline lens and intraocular lens tilt using a swept-source optical coherence tomography biometer[J]. J Cataract Refract Surg, 2019, 45(1): 35-40. doi:10.1016/j.jcrs.2018.08.025.
[7] Findl O, Hirnschall N, Draschl P, et al. Effect of manual capsulorhexis size and position on intraocular lens tilt, centration, and axial position[J]. J Cataract Refract Surg, 2017, 43(7): 902-908. doi:10.1016/j.jcrs.2017.04.037.
[8] Chen XY, Gu XX, Wang W, et al. Characteristics and factors associated with intraocular lens tilt and decentration after cataract surgery[J]. J Cataract Refract Surg, 2020, 46(8): 1126-1131. doi:10.1097/j.jcrs.0000000000000219.
[9] Uzel MM, Ozates S, Koc M, et al. Decentration and tilt of intraocular lens after posterior capsulotomy[J]. Semin Ophthalmol, 2018, 33(6): 766-771. doi:10.1080/08820538.2018.1443146.
[10] Ding XX, Wang QM, Xiang LF, et al. Three-dimensional assessments of intraocular lens stability with high-speed swept-source optical coherence tomography[J]. J Refract Surg, 2020, 36(6): 388-394. doi:10.3928/1081597X-20200420-01.
[11] 邢晓杰, 汤欣, 宋慧, 等. 四种非球面人工晶状体植入术后倾斜和偏心的比较[J]. 中华眼科杂志, 2010, 46(4): 332-336. doi:10.3760/cma.j.issn.0412-4081.2010.04.011. XING Xiaojie, TANG Xin, SONG Hui, et al. Comparison of tilt and decentration of four different kinds of aspheric intraocular lenses implantation[J]. Chinese Journal of Ophthalmology, 2010, 46(4): 332-336. doi:10.3760/cma.j.issn.0412-4081.2010.04.011.
[12] 宁远, 王静, 张劲松. 非球面人工晶状体囊袋内植入术后稳定性变化的对比研究[J]. 中国医科大学学报, 2019, 48(4): 295-299. doi:10.12007/j.issn.0258-4646.2019.04.002. NING Yuan, WANG Jing, ZHANG Jinsong. Comparison of stability changes for different aspherical intraocular lenses implanted in the capsular bags[J]. Journal of China Medical University, 2019, 48(4): 295-299. doi:10.12007/j.issn.0258-4646.2019.04.002.
[13] Lawu T, Mukai K, Matsushima H, et al. Effects of decentration and tilt on the optical performance of 6 aspheric intraocular lens designs in a model eye[J]. J Cataract Refract Surg, 2019, 45(5): 662-668. doi:10.1016/j.jcrs.2018.10.049.
[14] Holladay JT, Piers PA, Koranyi G, et al. A new intraocular lens design to reduce spherical aberration of pseudophakic eyes[J]. J Refract Surg, 2002, 18(6): 683-691. doi:10.3928/1081-597X-20021101-04.
[15] Taketani F, Matuura T, Yukawa E, et al. Influence of intraocular lens tilt and decentration on wavefront aberrations[J]. J Cataract Refract Surg, 2004, 30(10): 2158-2162. doi:10.1016/j.jcrs.2004.02.072.
[16] Pérez-Gracia J, Varea A, Ares J, et al. Evaluation of the optical performance for aspheric intraocular lenses in relation with tilt and decenter errors[J]. PLoS One, 2020, 15(5): e0232546. doi:10.1371/journal.pone.0232546.
[17] Eppig T, Scholz K, Löffler A, et al. Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye[J]. J Cataract Refract Surg, 2009, 35(6): 1091-1100. doi:10.1016/j.jcrs.2009.01.034.
[18] McKelvie J, McArdle B, McGhee C. The influence of tilt, decentration, and pupil size on the higher-order aberration profile of aspheric intraocular lenses[J]. Ophthalmology, 2011, 118(9): 1724-1731. doi:10.1016/j.ophtha.2011.02.025.
[19] Fujikado T, Saika M. Evaluation of actual retinal images produced by misaligned aspheric intraocular lenses in a model eye[J]. Clin Ophthalmol, 2014, 8: 2415-2423. doi:10.2147/OPTH.S72053.
[20] Nanavaty MA, Spalton DJ, Marshall J. Effect of intraocular lens asphericity on vertical Coma aberration[J]. J Cataract Refract Surg, 2010, 36(2): 215-221. doi:10.1016/j.jcrs.2009.08.024.
[21] Mester U, Sauer T, Kaymak H. Decentration and tilt of a single-piece aspheric intraocular lens compared with the lens position in young phakic eyes[J]. J Cataract Refract Surg, 2009, 35(3): 485-490. doi:10.1016/j.jcrs.2008.09.028.
[22] Pérez-Merino P, Marcos S. Effect of intraocular lens decentration on image quality tested in a custom model eye[J]. J Cataract Refract Surg, 2018, 44(7): 889-896. doi:10.1016/j.jcrs.2018.02.025.
[23] He W, Qiu X, Zhang S, et al. Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer[J]. Eye(Lond), 2018, 32(7): 1237-1243. doi:10.1038/s41433-018-0068-5.
[24] Xu J, Zheng TY, Lu Y. Effect of decentration on the optical quality of monofocal, extended depth of focus, and bifocal intraocular lenses[J]. J Refract Surg, 2019, 35(8): 484-492. doi:10.3928/1081597X-20190708-02.
[25] Liu X, Xie L, Huang Y. Effects of decentration and tilt at different orientations on the optical performance of a rotationally asymmetric multifocal intraocular lens[J]. J Cataract Refract Surg, 2019, 45(4): 507-514. doi:10.1016/j.jcrs.2018.10.045.
[26] Felipe A, Artigas JM, Díez-Ajenjo A, et al. Modulation transfer function of a toric intraocular lens: evaluation of the changes produced by rotation and tilt[J]. J Refract Surg, 2012, 28(5): 335-340. doi:10.3928/1081597X-20120321-01.
[27] Pérez-Vives C, Ferrer-Blasco T, Madrid-Costa D, et al. Optical quality of aspheric toric intraocular lenses at different degrees of decentering[J]. Albrecht Von Graefes Arch Fur Klinische Und Exp Ophthalmol, 2014, 252(6): 969-975. doi:10.1007/s00417-014-2629-z.
[28] 李承霖, 崔红, 李正日, 等. 波前像差光路系统检测IOL倾斜和偏心对光学成像质量的影响[J]. 国际眼科杂志, 2019, 19(12): 2071-2075. doi:10.3980/j.issn.1672-5123.2019.12.17. LI Chenglin, CUI Hong, LI Zhengri, et al. Effect of inclination and eccentricity of intraocular lens on optical imaging quality detected by wavefront aberration system[J]. International Eye Science, 2019, 19(12): 2071-2075. doi:10.3980/j.issn.1672-5123.2019.12.17.
[29] Madrid-Costa D, Pérez-Vives C, Ruiz-Alcocer J, et al. Visual simulation through different intraocular lenses in patients with previous myopic corneal ablation using adaptive optics: effect of tilt and decentration[J]. J Cataract Refract Surg, 2012, 38(5): 774-786. doi:10.1016/j.jcrs.2011.11.036.
[30] Fernández J, Rodríguez-Vallejo M, Martínez J, et al. Patient selection to optimize near vision performance with a low-addition trifocal lens[J]. J Optom, 2020, 13(1): 50-58. doi:10.1016/j.optom.2019.06.003.
[31] Zhang F, Zhang J, Li W, et al. Correlative comparison of three ocular axes to tilt and decentration of intraocular lens and their effects on visual acuity[J]. Ophthalmic Res, 2020, 63(2): 165-173. doi:10.1159/000504716.
[32] Holladay JT, Simpson MJ. Negative Dysphotopsia: causes and rationale for prevention and treatment[J]. J Cataract Refract Surg, 2017, 43(2): 263-275. doi:10.1016/j.jcrs.2016.11.049.
[33] Weikert MP, Golla A, Wang L. Astigmatism induced by intraocular lens tilt evaluated via ray tracing[J]. J Cataract Refract Surg, 2018, 44(6): 745-749. doi:10.1016/j.jcrs.2018.04.035.
[34] Tandogan T, Son HS, Choi CY, et al. Laboratory evaluation of the influence of decentration and pupil size on the optical performance of a monofocal, bifocal, and trifocal intraocular lens[J]. J Refract Surg, 2017, 33(12): 808-812. doi:10.3928/1081597X-20171004-02.
[35] Pilger D, Homburg D, Brockmann T, et al. Clinical outcome and higher order aberrations after bilateral implantation of an extended depth of focus intraocular lens[J]. Eur J Ophthalmol, 2018, 28(4): 425-432. doi:10.1177/1120672118766809.
[36] 韩玉彤, 陈彬川, 朱光举, 等. 超声生物显微镜观察囊袋张力环应用后人工晶状体的偏心量和倾斜度[J]. 眼科新进展, 2017, 37(6): 562-565. doi:10.13389/j.cnki.rao.2017.0142. HAN Yutong, CHEN Binchuan, ZHU Guangju, et al. Decentration and tilt of IOL after capsule tension ring implantation observed by ultrasonic biomicroscope[J]. Recent Advances in Ophthalmology, 2017, 37(6): 562-565. doi:10.13389/j.cnki.rao.2017.0142.
[37] 魏佩佩. 多焦点人工晶体植入术后的视觉质量及并发症[J]. 山东大学耳鼻喉眼学报, 2021, 35(2): 141-146. doi:10.6040/j.issn.1673-3770.0.2020.164. WEI Peipei. Visual quality and complications after implantation of multifocal intraocular lens[J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(2): 141-146. doi:10.6040/j.issn.1673-3770.0.2020.164.
[38] 杨丽, 李小禹, 兰长骏, 等. Nd: YAG激光后囊膜切开术对人工晶状体位置的影响: 基于CASIA2的研究[J]. 眼科新进展, 2021, 41(8): 759-764. doi:10.13389/j.cnki.rao.2021.0158. YANG Li, LI Xiaoyu, LAN Changjun, et al. Effect of Nd: YAG laser capsulotomy on the position of intraocular lens by CASIA2[J]. Recent Advances in Ophthalmology, 2021, 41(8): 759-764. doi:10.13389/j.cnki.rao.2021.0158.
[1] DUAN Lian, MENG FanlanReview,DANG GuangfuGuidance. Effect of dry eye on refractive cataract surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 1-6.
[2] SUN JiOverview,LI CanGuidance. Prediction and stability of axial intraocular lens position after cataract surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 7-12.
[3] HUANG ZiyanOverview,DUAN GuopingGuidance. Effect of higher-order aberrations on visual quality after cataract intraocular lens implantation [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(6): 13-18.
[4] HU Zunxia, SIMA Jing, QIN Bo, CAO Jiaguo, PAN Wei. Comparative study on the use of contact lens in Nd: YAG laser posterior capsulotomy [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(5): 41-45.
[5] DAI ChengOverview,LI BinzhongGuidance. Advances in multifocal soft corneal contact lens research [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(5): 100-105.
[6] YANG Ru, ZHANG Yuguang, XU Xianghui, WU Xuelian, TAO Yuan, TAN Yue. A clinical study on the effect of phacoemulsification on the retinal structure in the macular region of senile cataract [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(4): 97-102.
[7] LI Jing, ZHANG Hui, WANG Jing. A clinical study on the effect of using different intraocular lens implants on visual quality [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(2): 90-95.
[8] PENG Jiao, ZHONG Dingjuan, CHEN Jiao, ZUO Jun, WANG Hua. The effect of the relationship between the diameter of the optical zone and the diameter of the dark pupil on the visual quality of patients with different degrees of myopia after SMILE [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(2): 100-107.
[9] LI Bin, FANG Xuejun, WU De, HUANG Min. Agreement study of implantable collamer lens based on NK and KS formulas in the early stage after surgery [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(6): 33-41.
[10] HAI Yue,LIAO Xuan. Research progress and clinical application of Catquest-9SF [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(6): 142-146.
[11] WANG Shushu, FU Yahui, YU Ruoyu, HOU Yi, YANG Jiguo. The law of medication for the treatment of endogenous eye disease in chinese medical code based on data mining [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(4): 81-87.
[12] FU Yihao, XU Yixuan,YAN Hong, ZHANG Jie. Recent research advances in the role of glutaredoxin in oculopathy [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(3): 125-130.
[13] WEI Peipei,LI Can. Visual quality and complications after implantation of multifocal intraocular lens [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(2): 141-146.
[14] To explore the best method for diagnosis and treatments of post-surgical posterior ischemic optic neuropathy(PION). MethodsReview the medical records of a 78-year-old female patient who presented with sudden vision loss in her right eye on the fourth day after phacoemulsification and implantation of a posterior chamber intraocular lens in other hospital. After the electrophysiological examination and fundus fluorescein angiography, the patient was diagnosed as posterior ischemic optic neuropathy after cataract surgery in his right eye. She was administered with a retrobulbar injection of Anisodamine and placed on steroid pulse therapy. ResultsOn the 19th day after treatment, her visual acuity had recovered to 0.05. ConclusionThis is a rare case, and since post-surgical posterior ischemic optic neuropathy(PION)has no definite and effective treatment yet, active vigilance should be maintained before surgery. Detailed systemic history and physical examination are important for patients with high risks of developing PION, especially for evaluating their systemic hemodynamics. To sum up, PION should be considered in patients who have sudden severe vision loss and/or visual field defects with no obvious changes in the fundus after excluding other optic nerve diseases.. Posterior ischemic optic neuropathy after cataract surgery: a case report and literature reviewWANG Zongyi, QU Jinfeng Department of Ophthalmology, Peking University Peoples Hospital, Beijing 100044, ChinaAbstract:Objective〓 [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2020, 34(4): 56-59.
[15] LI Ying, JIANG Yang. A discussion on the choice of surgical methods for correction of myopia [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2020, 34(2): 1-6.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   