山东大学耳鼻喉眼学报 ›› 2019, Vol. 33 ›› Issue (6): 95-98.doi: 10.6040/j.issn.1673-3770.0.2019.275

• • 上一篇    

人工晶体度数计算公式的研究进展

谭燕,李灿   

  1. 重庆医科大学附属第一医院眼科/ 眼科学重庆市重点实验室/ 重庆市眼科研究所, 重庆 400016
  • 发布日期:2019-12-23

Progress in the research of intraocular lens power calculation formulas

TAN Yan, LI Can   

  1. Department of Ophthalmology, the First Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory of Ophthalmology, Chongqing Institute of Ophthalmology, Chongqing 400016, China
  • Published:2019-12-23

摘要: 随着屈光性白内障超声乳化手术的发展,人工晶状体度数的计算越来越受到重视,为了优化手术后的视觉质量,不断出现了各种人工晶体公式,论文综合论述了各种人工晶体度数计算公式如第一代人工晶体度数计算公式,第二代公式、Hill-RBF、 Barrett True-K等的研究进展。

关键词: 人工晶体公式, 白内障手术, 晶状体度数计算

Abstract: With the development of phacoemulsification surgery, the calculation of intraocular lens power has been paid greater attention. Various intraocular lens power formulas have been presented to optimize the visual quality after surgery. This paper comprehensively describes the progress in the research of various intraocular lens power formulas, such as the first-generation intraocular lens formula, the second-generation formula, Hill-RBF, Barrett True-K, and so on.

Key words: Intraocular lens formula, Cataract surgery, Calculation of lens power

中图分类号: 

  • R773.4
[1] Martinez-Enriquez E, Pérez-Merino P, Durán-Poveda S, et al. Estimation of intraocular lens position from full crystalline lens geometry: towards a new generation of intraocular lens power calculation formulas[J]. Sci Rep, 2018, 8(1): 9829. doi:10.1038/s41598-018-28272-6.
[2] Retzlaff JA, Sanders DR, Kraff MC. Development of the SRK/T intraocular lens implant power calculation formula[J]. J Cataract Refract Surg, 1990, 16(3): 333-340. doi:10.1016/s0886-3350(13)80705-5.
[3] Fyodorov SN, Galin MA, Linksz A. Calculation of the optical power of intraocular lenses[J]. Invest Ophthalmol, 1975, 14(8): 625-628.
[4] Sanders DR, Retzlaff J, Kraff MC. Comparison of the SRK II formula and other second generation formulas[J]. J Cataract Refract Surg, 1988, 14(2): 136-141. doi:10.1016/s0886-3350(88)80087-7.
[5] Hoffer KJ. The Hoffer Q formula: a comparison of theoretic and regression formulas[J]. J Cataract Refract Surg, 1993, 19(6): 700-712. doi:10.1016/s0886-3350(13)80338-0.
[6] Cooke DL, Cooke TL. Prediction accuracy of preinstalled formulas on 2 optical biometers[J]. J Cataract Refract Surg, 2016, 42(3): 358-362. doi:10.1016/j.jcrs.2015.11.040.
[7] Gökce SE, Zeiter JH, Weikert MP, et al. Intraocular lens power calculations in short eyes using 7 formulas[J]. J Cataract Refract Surg, 2017, 43(7): 892-897. doi:10.1016/j.jcrs.2017.07.004.
[8] Hoffer KJ, Savini G. IOL Power Calculation in Short and Long Eyes[J]. Asia Pac J Ophthalmol(Phila), 2017, 6(4): 330-331. doi:10.22608/APO.2017338.
[9] Chen C, Xu X, Miao YY, et al. Accuracy of intraocular lens power formulas involving 148 eyes with long axial lengths: A retrospective chart-review study[J]. J Ophthalmol, 2015, 2015: 976847. doi:10.1155/2015/976847.
[10] Hoffer KJ. Clinical results using the Holladay 2 intraocular lens power formula[J]. J Cataract Refract Surg, 2000, 26(8): 1233-1237. doi:10.1016/s0886-3350(00)00376-x.
[11] Terzi E, Wang L, Kohnen T. Accuracy of modern intraocular lens power calculation formulas in refractive lens exchange for high myopia and high hyperopia[J]. J Cataract Refract Surg, 2009, 35(7): 1181-1189. doi:10.1016/j.jcrs.2009.02.026.
[12] Roessler GF, Dietlein TS, Plange N, et al. Accuracy of intraocular lens power calculation using partial coherence interferometry in patients with high myopia[J]. Ophthalmic Physiol Opt, 2012, 32(3): 228-233. doi:10.1111/j.1475-1313.2012.00903.x.
[13] Bang S, Edell E, Yu QL, et al. Accuracy of intraocular lens calculations using the IOLMaster in eyes with long axial length and a comparison of various formulas[J]. Ophthalmology, 2011, 118(3): 503-506. doi:10.1016/j.ophtha.2010.07.008.
[14] Wang QW, Jiang W, Lin T, et al. Accuracy of intraocular lens power calculation formulas in long eyes: a systematic review and meta-analysis[J]. Clin Experiment Ophthalmol, 2018, 46(7): 738-749. doi:10.1111/ceo.13184.
[15] Roberts TV, Hodge C, Sutton G, et al. Comparison of Hill-radial basis function, Barrett Universal and current third generation formulas for the calculation of intraocular lens power during cataract surgery[J]. Clin Experiment Ophthalmol, 2018, 46(3): 240-246. doi:10.1111/ceo.13034.
[16] Kang BS, Han JM, Oh JY, et al. Intraocular lens power calculation after refractive surgery: a comparative analysis of accuracy and predictability[J]. Korean J Ophthalmol,2017,31(6):479-488. doi: 10.3341/ kjo. 2016.0078.
[1] 唐唯,李元彬. 屈光性白内障手术新进展[J]. 山东大学耳鼻喉眼学报, 2019, 33(2): 149-158.
[2] 毕宏生. 精准屈光性白内障手术规划[J]. 山东大学耳鼻喉眼学报, 2017, 31(4): 1-4.
[3] 孙洪义, 张晗. 2型糖尿病患者超声乳化白内障摘除并人工晶体植入手术后黄斑区光学相干断层扫描改变[J]. 山东大学耳鼻喉眼学报, 2014, 28(6): 72-76.