Correlation analysis of LDV femtosecond laser flap and corneal curvature

DING Xin, YU Chen-ying, AI Feng-rong, CHEN Bing-jun, LI Ying   

  1. Department of Ophthalmology, Beijing Union Medical College Hospital, Beijing 100730, China
  • Received:2013-06-18 Published:2013-08-16

摘要:

目的    分析达芬奇(LDV)飞秒激光所制作的角膜瓣横径与角膜曲率(K)值的相关性,为临床上不同角膜曲率患者选择角膜瓣的制作方法提供依据。方法    随机选取进行飞秒激光制瓣的准分子激光原位角膜磨镶术矫治近视的患者50例(100眼),根据飞秒制作角膜瓣所采用的吸引环直径分为两组,其中Ⅰ组13例(26眼)采用9.0mm吸引环,Ⅱ组37例(74眼)采用8.5mm吸引环。于手术台上测量并记录角膜曲率、角膜横径及瓣横径,手术由同一位医生完成。采用独立样本t检验及双变量相关分析的统计方法对数据进行分析。结果    样本的年龄范围为18~37岁(平均25岁), 其中男18例(36眼), 女32例(64眼),均为双眼手术,且无术中并发症发生。结果显示,两组角膜横径平均值分别为10.7mm和10.6mm(t=0.04,P>0.05);其中Ⅰ组平均角膜瓣横径9.2mm,K值>44.0D、44.0D~42.0D、<42.0D患者角膜瓣的横径分别为9.3mm、9.1mm、8.6mm,K值与角膜瓣横径存在显著正相关(r=0.492,P=0.027) ;Ⅱ组平均角膜瓣横径8.3mm;K值>44.0D、44.0D ~42.0D、<42.0D角膜瓣的横径分别为8.4mm、8.3mm、8.0mm (r=0.513,P=0.001)。结论    LDV飞秒激光制作角膜瓣的横径大小与K值有密切的相关性,K值高者角膜瓣相对偏大,K值越低则角膜瓣越小。提示角膜曲率低的患者在手术时尽量选用偏大的吸引环,而避免因选择了直径小的吸引环导致的小瓣、游离瓣。角膜曲率高的患者宜选用偏小的吸引环,避免因选择了直径大的吸引环导致的瓣过大、手术中出血、术后干眼等。

关键词: 角膜瓣, 相关性, 达芬奇飞秒激光, 角膜曲率

Abstract:

Objective    To evaluate the correlation between diameter of corneal flap created by LDV femtosecond laser and corneal curvature (K), so as to provide clinical evidence for the choice of suction ring to satisfy patients with different corneal curvature. Methods    Fifty myopic patients (100 eyes) who had femtosecond-assisted LASIK surgery from February to April 2013 in Peking Union Medical College Hospital were included in this study. Patients were divided into two groups based on the diameter of suction ring used in the creation of corneal flap. Thirteen patients (26 eyes) who used suction ring of 9.0mm were in Group Ⅰ, while the other thirty-seven patients (74 eyes) who used suction ring of 8.5mm were in Group Ⅱ. All the procedures were done by the same skillful surgeon who also measured the diameter of the cornea and the flap, and the corneal curvature during each procedure. An independent samples t test and bivariate correlation method were used to analyze the quantitative data. Results    There were eighteen males (36 eyes) and thirtytwo females (64 eyes) in this study aged 18 to 37 (average 24.6) years old. Patients all underwent binocular surgery and no intra-operative complication occurred. The average diameter of the cornea in each group was 10.7mm and 10.6mm respectively (t=0.04, P<0.05). The average diameter of the corneal flap in Group Ⅰ was 9.2mm, and for patients whose corneal curvature was greater than 44.0D, between 42.0D and 44.0D, or less than 42.0D, their average corneal flap diameter was 9.3mm, 9.1mm, and 8.6mm respectively, which showed a significant positive correlation between the corneal curvature and the corneal flap diameter (r=0.492, P=0.027). The average diameter of the corneal flap in Group Ⅰ was 8.3mm, and for patients whose corneal curvature was greater than 44.0D, between 42.0D and 44.0D, or less than 42.0D, their average corneal flap diameter was 8.4mm, 8.3mm, and 8.0mm respectively, which also showed a significant positive correlation between the corneal curvature and corneal flap diameter (r=0.513, P=0.001). Conclusion    The diameter of corneal flap created by LDV femtosecond laser is strongly correlated with corneal curvature, meaning patients with a high K Value tended to have a bigger corneal flap than patients with a relatively low K Value in femtosecond-assisted LASIK surgery. It suggest that surgeons should choose suction rings that are relatively bigger for patients with a low K Value in order to prevent creation of small or even free corneal flaps. And for patients with a high K Value, suction rings that are relatively smaller are recommended, in order to prevent creation of large corneal flaps, intraoperative bleeding, and post-LASIK dry eye.

Key words: Corneal flap, Corneal curvature,  LDV femtosecond laser, Correlation

中图分类号: 

  • R778.1
[1] 朱明娟,邢凯,亢泽峰,刘健. 甲状腺相关性眼病的诊断及治疗进展[J]. 山东大学耳鼻喉眼学报, 2018, 32(5): 110-113.
[2] 谢洪彬,杨美娜,陈青山,刘旭阳,樊宁. IgG4相关性眼病伴继发性青光眼病例分析[J]. 山东大学耳鼻喉眼学报, 2018, 32(2): 99-102.
[3] 王磊, 张晗. 人工晶体屈光力的计算[J]. 山东大学耳鼻喉眼学报, 2017, 31(4): 21-28.
[4] 冀帅飞,张婕,严宏. 年龄相关性黄斑变性患者人工晶状体的选择[J]. 山东大学耳鼻喉眼学报, 2017, 31(4): 36-39.
[5] 王翠,颜昕,赵博军. IVR联合PDT治疗湿性年龄相关性黄斑变性的临床观察[J]. 山东大学耳鼻喉眼学报, 2017, 31(4): 94-97.
[6] 赵露,谢国丽,王艳玲. 玻璃体腔注射雷珠单抗对湿性年龄相关性黄斑变性患者眼血流动力学的影响[J]. 山东大学耳鼻喉眼学报, 2016, 30(4): 101-104.
[7] 刘悦,赵雪,刘岩,金成勋,魏宁,金春顺,王三春. IgG4相关性疾病4例报告并文献回顾[J]. 山东大学耳鼻喉眼学报, 2016, 30(3): 77-81.
[8] 陈春丽, 宋宗明, 贾新国, 周仲楼, 汪朝阳. 促红细胞生成素抑制氧化损伤诱导的人眼Müller细胞凋亡[J]. 山东大学耳鼻喉眼学报, 2015, 29(3): 65-71.
[9] 严涛, 栾国刚, 谌金金, 陈雯. 角膜塑形镜矫正近视对青少年眼屈光系统及眼压的影响[J]. 山东大学耳鼻喉眼学报, 2015, 29(1): 69-71.
[10] 张秋露,王永华,李颖,王玥,柳静,胡雅斌,徐雯,郑燕,刘倩,翟长斌. 飞秒激光Ziemer FEMTO LDV “Classic”和“Crystal Line” 制作LASIK角膜瓣的评估[J]. 山东大学耳鼻喉眼学报, 2014, 28(3): 75-79.
[11] 闻华明1,李海祥2. 应用三角函数法估算LASIK术后人工晶状体度数[J]. 山东大学耳鼻喉眼学报, 2013, 27(5): 74-76.
[12] 张爱慧1,朱灵1,张金枝1,张伟2. 白内障超声乳化人工晶体植入术与年龄相关性黄斑变性的相关性研究[J]. 山东大学耳鼻喉眼学报, 2013, 27(5): 77-83.
[13] 邵雁1,徐新荣2. 中药治疗年龄相关性黄斑变性研究进展[J]. 山东大学耳鼻喉眼学报, 2013, 27(5): 91-94.
[14] 翟长斌1,郝颖娟2,易省平2,杨庆松1,张晶1,周跃华1. 鹰视飞秒FS200与Moria M2110微型角膜板层刀制作的角膜瓣厚度及形态观察[J]. 山东大学耳鼻喉眼学报, 2013, 27(4): 21-25.
[15] 曹广义,薛劲松. Ziemer FEMTO LDV飞秒激光制作角膜瓣的特点分析[J]. 山东大学耳鼻喉眼学报, 2013, 27(4): 36-39.
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
No Suggested Reading articles found!