Abstract: Objective To explore the significance of the 1 000 Hz acoustic immittance test combined with automatic auditory brainstem response(AABR)and distortion product otoacoustic emission(DPOAE)in hearing screenings of high-risk newborns. Methods A total of 318 high-risk newborns(636 ears)were included as the research subjects. The triple hearing screening scheme of AABR + DPOAE + 1 000 Hz acoustic immittance was adopted. The newborns who failed the screening test were examined for diagnostic hearing at 3 months of age, and the sensitivity, specificity, missed diagnosis rate, false diagnosis rate, and accuracy of the triple screening results were calculated. In this study, the normal triple screening results included AABR(-)DPOAE(+)acoustic immittance(+), AABR(-)DPOAE(-)acoustic immittance(+), and AABR(-)DPOAE(-)acoustic immittance(-). The abnormal triple screening results include AABR(+)DPOAE(+)acoustic immittance(+), AABR(+)DPOAE(+)acoustic immittance(-), AABR(+)DPOAE(-), AABR(-)DPOAE(+)acoustic immittance(-), and AABR(+)DPOAE(-)acoustic immittance(-). Results A total of 318 high-risk newborns(636 ears)were included. The sensitivity of triple screening(96.77%)was higher than that of the AABR-only screening method(80.64%)and DPOAE-only screening method(83.87%), which was consistent with that of the double AABR + OAE screening method(96.77%). The specificity of triple screening(91.24%)was higher than that of AABR + OAE double screening(87.44%). Triple screening can further reduce the false-positive rate of double screening and is suitable for high-risk neonatal screening. Conclusion Triple screening has high sensitivity and a low missed diagnosis rate for hearing screening of high-risk newborns. Triple hearing examinations can be applied to hearing screening of high-risk newborns. Some false-positive infants with simple middle-ear dysfunction can be screened out in the early stage, which can alleviate parental anxiety.

Key words: High-risk infants, Hearing screening, Automated auditory brainstem response, Distortion product otoacoustic emission, 1 000 Hz acoustic immittance, Combined screening

CLC Number: 

  • R764
[1] 黄丽辉.解读2010年版新生儿听力筛查技术规范[J].听力学及言语疾病杂志,2011,19(6):495-496.
[2] 陈惠球, 陈敬国, 黄超. 早产儿AABR听力筛查初筛时间探讨[J]. 实用临床护理学电子杂志, 2017, 2(11): 124-125. doi:10.3969/j.issn.2096-2479.2017.11.097. CHEN Huiqiu, CHEN Jingguo, HUANG Chao. The effect of different initial screening times on the rate of spontaneous auditory brainstem response in preterm infants[J]. Journal of Clinic Nursing's Practicality, 2017, 2(11): 124-125. doi:10.3969/j.issn.2096-2479.2017.11.097.
[3] 史冬梅, 益欢欢, 史霞, 等. 自动听性脑干反应及耳声发射联合使用在新生儿听力筛查中临床意义[J]. 中华耳科学杂志, 2018, 16(2): 199-204. doi:10.3969/j.issn.1672-2922.2018.02.014. SHI Dongmei, YI Huanhuan, SHI Xia, et al. Combined automatic auditory brainstem response and otoacoustic emissions hearing screening in newborns with different disease statuses and gestational ages[J]. Chinese Journal of Otology, 2018, 16(2): 199-204. doi:10.3969/j.issn.1672-2922.2018.02.014.
[4] 倪道凤. 婴幼儿分泌性中耳炎[J]. 中国医学文摘(耳鼻咽喉科学), 2007, 22(1): 11-13. doi:10.19617/j.issn1001-1307.2007.01.008.
[5] 江载芳, 申昆玲, 沈颖. 诸福棠实用儿科学[M]. 8版. 北京: 人民卫生出版社, 2015.
[6] 刘敏, 李晓璐, 张璐, 等. 自动听性脑干反应联合声导抗鼓室图在疑似听力障碍婴幼儿中的应用[J]. 中国儿童保健杂志, 2018, 26(9): 1038-1041. doi:10.11852/zgetbjzz2018-26-09-29. LIU Min, LI Xiaolu, ZHANG Lu, et al. Application of automated auditory brainstem response combined with acoustic immitance testing in infants with suspected hearing loss[J]. Chinese Journal of Child Health Care, 2018, 26(9): 1038-1041. doi:10.11852/zgetbjzz2018-26-09-29.
[7] 王肃旸, 丁文娟, 才让卓玛, 等. 甘南州1 378例DPOAE联合AABR新生儿听力筛查结果分析[J]. 中国医学文摘-耳鼻咽喉科学, 2018, 33(4): 309-311. doi:10.19617/j.issn1001-1307.2018.04.309. WANG Suyang, DING Wenjuan, CAI Rangzhuoma, et al. Research on the incidence of newborns hearing impairment by DPOAE and AABR in Gannan state: an analysis of 1 378 neonates[J]. Chinese Medical Digest(Otorhinolaryngology), 2018, 33(4): 309-311. doi:10.19617/j.issn1001-1307.2018.04.309.
[8] Akinpelu OV, Funnell WRJ, Daniel SJ. High-frequency otoacoustic emissions in universal newborn hearing screening[J]. Int J Pediatr Otorhinolaryngol, 2019, 127: 109659. doi: 10.1016/j.ijporl.2019.109659.
[9] Iley KL, Addis RJ. Impact of technology choice on service provision for universal newborn hearing screening within a busy district hospital[J]. J Perinatol, 2000, 20(1): S122-S127. doi:10.1038/sj.jp.7200443.
[10] Ravi R, Gunjawate DR, Yerraguntla K, et al. Follow-up in newborn hearing screening-A systematic review[J]. Int J Pediatr Otorhinolaryngol, 2016, 90: 29-36. doi:10.1016/j.ijporl.2016.08.016.
[11] 许安廷,张长平,杜尊民.新生儿听力筛查中的假阳性问题[J].山东大学耳鼻喉眼学报,2005,19(6):357-359. XU Anting, ZHANG Changping, DU Zunmin. False positives in newborn hearing screening[J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2005, 19(6): 357-359.
[12] Zaitoun M, Nuseir A. Parents' satisfaction with a trial of a newborn hearing screening programme in Jordan[J]. Int J Pediatr Otorhinolaryngol, 2020, 130: 109845. doi: 10.1016/j.ijporl.2019.109845.
[13] 周佳霖, 黄振云, 钟建文, 等. 36个月内婴幼儿1 000 Hz和226 Hz探测音声导抗的特点和意义[J]. 中华耳科学杂志, 2014, 9(3): 455-459. doi:10.3969/j.issn.1672-2922.2014.03.027. ZHOU Jialin, HUANG Zhenyun, ZHONG Jianwen, et al. Tympanometry at 1 000 Hz and 226 Hz in 1 645 infants[J]. Chinese Journal of Otology, 2014, 9(3): 455-459. doi:10.3969/j.issn.1672-2922.2014.03.027.
[14] de Lyra-Silva KA, Sanches SGG, Neves-Lobo IF, et al. Middle ear muscle reflex measurement in neonates: comparison between 1 000 Hz and 226 Hz probe tones[J]. Int J Pediatr Otorhinolaryngol, 2015, 79(9): 1510-1515. doi:10.1016/j.ijporl.2015.06.039.
[15] 张国军, 龚松阳. 骨导ABR与1 000 Hz声导抗对婴儿传导性聋检出率比较[J]. 中华耳科学杂志, 2016, 14(3): 374-377. doi:10.3969/j.issn.1672-2922.2016.03.012. ZHANG Guojun, GONG Songyang. Comparison between bone-conduction ABR and 1 000 Hz tympanomentry in detecting conductive hearing loss[J]. Chinese Journal of Otology, 2016, 14(3): 374-377. doi:10.3969/j.issn.1672-2922.2016.03.012.
[16] 刘敏, 李晓璐, 张璐, 等. 自动听性脑干反应联合声导抗鼓室图在疑似听力障碍婴幼儿中的应用[J]. 中国儿童保健杂志, 2018, 26(9): 1038-1041. doi:10.11852/zgetbjzz2018-26-09-29. LIU Min, LI Xiaolu, ZHANG Lu,et al. Application of automated auditory brainstem response combined with acoustic immitance testing in infants with suspected hearing loss[J]. Chinese Journal of Child Health Care, 2018, 26(9): 1038-1041. doi:10.11852/zgetbjzz2018-26-09-29.
[17] 姚寿国, 史波宁, 陈淑飞, 等. 1 000 Hz探测音声导抗检查在新生儿听力筛查中的应用价值[J]. 听力学及言语疾病杂志, 2020, 28(6): 653-655. doi:10.3969/j.issn.1006-7299.2020.06.010. YAO Shouguo, SHI Boning, CHEN Shufei, et al. Application value of 1 000 Hz high frequency immitance test in newborn hearing screening[J]. Journal of Audiology and Speech Pathology, 2020, 28(6): 653-655.doi:10.3969/j.issn.1006-7299.2020.06.010.
[18] Kanji A, Khoza-Shangase K, Moroe N. Newborn hearing screening protocols and their outcomes: a systematic review[J]. Int J Pediatr Otorhinolaryngol,2018,115:104-109. doi: 10.1016/j.ijporl.2018.09.026.
[1] PAN Linlin, FANG Xuhua, ZHAI Feng, GUI Yiding, BIAN Zhouliang, CHEN Jie. The correlation between arterial blood gas analysis and hearing screening results in neonates [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(1): 20-24.
[2] PAN Linlin, KONG LingyiOverview,ZHAI Feng, CHEN JieGuidance. Research progress on auditory risk factors and hearing screening methods among neonates [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2022, 36(1): 131-137.
[3] LI Yuanchao, WU Wei, WANG Gang, QU Changbei, WANG Lei, LU Wenjun, LI Dan, HAN Haolun, LIU Gang. Effects of simulated weightlessness and continuous noise in a spaceship on auditory function of rats [J]. Journal of Otolaryngology and Ophthalmology of Shandong University, 2021, 35(5): 11-16.
[4] ZHOU Jialei, SUN Shibing, LI Jingyu, CHEN Fang, LI Xiaoyan. Comparison and significance of different automated auditory brainstem response testing times in infants [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2018, 32(2): 66-69.
[5] WANG Guoqiang, ZHAO Chunhong, HUO Hong, GONG Zhiyun, SONG Weiwei, YAN Lixia, LI Xuehua, WANG Weili. Hearing screening and risk factors of hearing impairment in premature infants. [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2015, 29(4): 7-10.
[6] ZHOU Xiao-wei, WANG Yue-jian, DUAN Guang-rong, YU You-jun. The establishment of a hearing clinic network [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2014, 28(6): 79-84.
[7] YU Chong-xian, YANG Ke-lin, ZHANG Xiao-min, WANG Ping. Objective hearing evaluation of infants failed in hearing screening [J]. J Otolaryngol Ophthalmol Shandong Univ, 2013, 27(6): 38-41.
[8] LIU Zhi-qi1,2, LIU Li-si1, YANG Kun3. Hearing screenings  in 11894 infants [J]. J Otolaryngol Ophthalmol Shandong Univ, 2013, 27(2): 8-12.
[9] ZHANG En-dong, LI Da-jian, MIAO Le-jie. Comparative study of newborn hearing screening between the neonatal intensive care unit and wellbaby nursery [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2011, 25(2): 29-31.
[10] ZHANG Dun-Yao, SHU Fu-Gao, SUN Mei-Gong. Results and analysis of 6?159 newborn hearing screening [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2009, 23(4): 38-40.
[11] YANG Kun,LIU Zhi-qi,HUANG Zhi-wu . Clinical guidelines for usage of 226- and 1,000-Hz tympanometry in
normal neonates
[J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2008, 22(5): 420-423 .
Viewed
Full text


Abstract

Cited

  Shared   
  Discussed   
[1] MA Bao-feng,DANG Guang-fu .

Trans-scleral suture fixation in implantation of foldable intraocular lenses

[J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2008, 22(4): 376 -378 .
[2] FENG Xin-rong,ZHANG Hong-xia,XU Zhen-ji,QU Jun-jun, . [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2006, 20(3): 225 -226 .
[3] ZHANG Qiu-gui,HE Hai-yan . [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2006, 20(6): 520 -521 .
[4] LI Hai-yan,ZHAO Qiu-liang,HAN Xiao-pan,YU li . [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2006, 20(6): 527 -529 .
[5] SONG Xi-cheng,ZHANG hua,ZHANG Qing-quan . [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2006, 20(5): 385 -387 .
[6] ZHAN Shan-qiang,KONG Fan-li,CAO Wen-juan,TANG Jie . [J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2006, 20(6): 559 -560 .
[7] ZHANG Hu,AI Qin . Re-operation for thyroid cancer[J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2007, 21(2): 166 -167 .
[8] HU Ming,LI Zhao-na,LI Yun-jie ,TAO Xiang-chen . Effect of rigid gas permeable contact lens on keratoconus[J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2007, 21(2): 171 -173 .
[9] LOU Feng . Effect of bilateral superior laryngeal nerve block on preventing cardiovascular reaction[J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2008, 22(2): 173 -175 .
[10] CHEN Wei-Xiong, WANG Yue-Jian, CENG Yong, HE Fa-Yao, ZHANG Jian-Li, ZHENG Li-Gang, TANG Su-Cheng. Clinical experience of no-insufflation endoscopic thyroidectomy by a small incision upon the sternum[J]. JOURNAL OF SHANDONG UNIVERSITY (OTOLARYNGOLOGY AND OPHTHALMOLOGY), 2009, 23(4): 24 -26 .