山东大学耳鼻喉眼学报 ›› 2020, Vol. 34 ›› Issue (2): 72-78.doi: 10.6040/j.issn.1673-3770.1.2020.016
王暄琪,陈珣综述王晓瑛审校
WANG Xuanqi,CHEN XunReview,WANG XiaoyingGuidance
摘要: 可植入式眼内镜植入术是一种安全、有效、稳定的近视矫正手术,已在全世界广泛开展。植入的人工晶状体后表面到自身晶状体前表面的最大垂直距离称为拱高,是一项保证手术安全性的重要术后随访指标,过高或过低的拱高均可能引起某些并发症,影响术后临床效果。如何精确测量、准确计算以获得理想拱高,如何处理偏大或偏小的拱高以减少术后并发症,一直是学者们研究的热点。以拱高为中心,综述其影响因素及相关并发症,为提高手术安全性、减少手术并发症提供临床依据,为临床研究探索方向。
中图分类号:
[1] Khalifa YM, Goldsmith J, Moshirfar M. Bilateral explantation of Visian Implantable Collamer Lenses secondary to bilateral acute angle closure resulting from a non-pupillary block mechanism[J]. J Refract Surg, 2010, 26(12): 991-994. doi:10.3928/1081597X-20100521-01. [2] Gonvers M, Bornet C, Othenin-Girard P. Implantable contact Lens for moderate to high myopia: relationship of vaulting to cataract formation[J]. J Cataract Refract Surg, 2003, 29(5): 918-924. doi:10.1016/s0886-3350(03)00065-8. [3] Cao XF, Wu WL, Wang Y, et al. Comparison over time of vault in Chinese eyes receiving implantable contact lenses with or without a central hole[J]. Am J Ophthalmol, 2016, 172: 111-117. doi:10.1016/j.ajo.2016.09.016. [4] Kamiya K, Shimizu K, Ando W, et al. Comparison of vault after implantation of posterior chamber phakic intraocular Lens with and without a central hole[J]. J Cataract Refract Surg, 2015, 41(1): 67-72. doi:10.1016/j.jcrs.2014.11.011. [5] Guber I, Bergin C, Perritaz S, et al. Correcting interdevice Bias of horizontal white-to-white and sulcus-to-sulcus measures used for implantable collamer Lens sizing[J]. Am J Ophthalmol, 2016, 161: 116-125.e1. doi:10.1016/j.ajo.2015.09.037. [6] Wang L, Auffarth GU. White-to-white corneal diameter measurements using the eyemetrics program of the Orbscan topography system[J]. Dev Ophthalmol, 2002, 34: 141-146. doi:10.1159/000060793. [7] Gao J, Liao RF, Li N. Ciliary sulcus diameters at different anterior chamber depths in highly myopic eyes[J]. J Cataract Refract Surg, 2013, 39(7): 1011-1016. doi:10.1016/j.jcrs.2013.01.040. [8] Kawamorita T, Uozato H, Kamiya K, et al. Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter[J]. J Cataract Refract Surg, 2010, 36(4): 617-624. doi:10.1016/j.jcrs.2009.11.017. [9] Biermann J, Bredow L, Boehringer D, et al. Evaluation of ciliary sulcus diameter using ultrasound biomicroscopy in emmetropic eyes and myopic eyes[J]. J Cataract Refract Surg, 2011, 37(9): 1686-1693. doi:10.1016/j.jcrs.2011.03.048. [10] Packer M. Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer Lens[J]. Clin Ophthalmol, 2016, 10: 1059-1077. doi:10.2147/OPTH.S111620. [11] Baumeister M, Terzi E, Ekici Y, et al. Comparison of manual and automated methods to determine horizontal corneal diameter[J]. J Cataract Refract Surg, 2004, 30(2): 374-380. doi:10.1016/j.jcrs.2003.06.004. [12] Salouti R, Nowroozzadeh MH, Zamani M, et al. Comparison of Horizontal corneal diameter measurements using the Orbscan IIz and Pentacam HR systems[J]. Cornea, 2013, 32(11): 1460-1464. doi:10.1097/ICO.0b013e3182a40786. [13] Kohnen T, Thomala MC, Cichocki M, et al. Internal anterior chamber diameter using optical coherence tomography compared with white-to-white distances using automated measurements[J]. J Cataract Refract Surg, 2006, 32(11): 1809-1813. doi:10.1016/j.jcrs.2006.08.023. [14] Mori T, Yokoyama S, Kojima T, et al. Factors affecting rotation of a posterior chamber collagen copolymer toric phakic intraocular Lens[J]. J Cataract Refract Surg, 2012, 38(4): 568-573. doi:10.1016/j.jcrs.2011.11.028. [15] Zhang X, Chen X, Wang XY, et al. Analysis of intraocular positions of posterior implantable collamer Lens by full-scale ultrasound biomicroscopy[J]. BMC Ophthalmol, 2018, 18(1): 114. doi:10.1186/s12886-018-0783-5. [16] Li Z, Xu ZK, Wang YQ, et al. Implantable collamer Lens surgery in patients with primary Iris and/or ciliary body cysts[J]. BMC Ophthalmol, 2018, 18(1): 287. doi:10.1186/s12886-018-0935-7. [17] Gonzalez-Lopez F, Bilbao-Calabuig R, Mompean B, et al. Determining the potential role of crystalline Lens rise in vaulting in posterior chamber phakic collamer Lens surgery for correction of myopia[J]. J Refract Surg, 2019, 35(3): 177-183. doi:10.3928/1081597X-20190204-01. [18] Seo JH, Kim MK, Wee WR, et al. Effects of white-to-white diameter and anterior chamber depth on implantable collamer Lens vault and visual outcome[J]. J Refract Surg, 2009, 25(8): 730-738. doi:10.3928/1081597X-20090707-08. [19] Alfonso JF, Fernández-Vega L, Lisa C, et al. Central vault after phakic intraocular Lens implantation: correlation with anterior chamber depth, white-to-white distance, spherical equivalent, and patient age[J]. J Cataract Refract Surg, 2012, 38(1): 46-53. doi:10.1016/j.jcrs.2011.07.035. [20] Lee H, Kang DSY, Choi JY, et al. Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer Lens in myopic eyes[J]. BMC Ophthalmol, 2018, 18(1): 163. doi:10.1186/s12886-018-0835-x. [21] Choi JH, Lim DH, Nam SW, et al. Ten-year clinical outcomes after implantation of a posterior chamber phakic intraocular Lens for myopia[J]. J Cataract Refract Surg, 2019, 45(11): 1555-1561. doi:10.1016/j.jcrs.2019.06.015. [22] Schmidinger G, Lackner B, Pieh S, et al. Long-term changes in posterior chamber phakic intraocular collamer Lens vaulting in myopic patients[J]. Ophthalmology, 2010, 117(8): 1506-1511. doi:10.1016/j.ophtha.2009.12.013. [23] Guber I, Mouvet V, Bergin C, et al. Clinical outcomes and cataract formation rates in eyes 10 years after posterior phakic Lens implantation for myopia[J]. JAMA Ophthalmol, 2016, 134(5): 487-494. doi:10.1001/jamaophthalmol.2016.0078. [24] Atchison DA, Markwell EL, Kasthurirangan S, et al. Age-related changes in optical and biometric characteristics of emmetropic eyes[J]. J Vis, 2008, 8(4): 29.1-20. doi:10.1167/8.4.29. [25] Lee H, Kang SY, Seo KY, et al. Dynamic vaulting changes in V4c versus V4 posterior chamber phakic lenses under differing lighting conditions[J]. Am J Ophthalmol, 2014, 158(6): 1199-1204.e1. doi:10.1016/j.ajo.2014.08.020. [26] Petternel V, Köppl CM, Dejaco-Ruhswurm I, et al. Effect of accommodation and pupil size on the movement of a posterior chamber Lens in the phakic eye[J]. Ophthalmology, 2004, 111(2): 325-331. doi:10.1016/j.ophtha.2003.05.013. [27] Lee H, Kang DS, Ha BJ, et al. Effect of accommodation on vaulting and movement of posterior chamber phakic lenses in eyes with implantable collamer lenses[J]. Am J Ophthalmol, 2015, 160(4): 710-716.e1. doi:10.1016/j.ajo.2015.07.014. [28] Du CX, Wang JH, Wang XY, et al. Ultrasound biomicroscopy of anterior segment accommodative changes with posterior chamber phakic intraocular Lens in high myopia[J]. Ophthalmology, 2012, 119(1): 99-105. doi:10.1016/j.ophtha.2011.07.001. [29] Chen X, Miao HM, Naidu RK, et al. Comparison of early changes in and factors affecting vault following posterior chamber phakic Implantable Collamer Lens implantation without and with a central hole(ICL V4 and ICL V4c)[J]. BMC Ophthalmol, 2016, 16(1): 161. doi:10.1186/s12886-016-0336-8. [30] Lindland A, Heger H, Kugelberg M, et al. Vaulting of myopic and toric Implantable Collamer Lenses during accommodation measured with Visante optical coherence tomography[J]. Ophthalmology, 2010, 117(6): 1245-1250. doi:10.1016/j.ophtha.2009.10.033. [31] Garcia-De la Rosa G, Olivo-Payne A, Serna-Ojeda JC, et al. Anterior segment optical coherence tomography angle and vault analysis after toric and non-toric implantable collamer Lens V4c implantation in patients with high myopia[J]. Br J Ophthalmol, 2018, 102(4): 544-548. doi:10.1136/bjophthalmol-2017-310518. [32] Yan ZP, Miao HM, Zhao F, et al. Two-year outcomes of visian implantable collamer Lens with a central hole for correcting high myopia[J]. J Ophthalmol, 2018, 2018: 8678352. doi:10.1155/2018/8678352. [33] Fernández-Vigo JI, Macarro-Merino A, Fernández-Vigo C, et al. Impacts of implantable collamer Lens V4c placement on angle measurements made by optical coherence tomography: two-year follow-up[J]. Am J Ophthalmol, 2018, 186: 171-172. doi:10.1016/j.ajo.2017.10.034. [34] Dougherty PJ, Rivera RP, Schneider D, et al. Improving accuracy of phakic intraocular Lens sizing using high-frequency ultrasound biomicroscopy[J]. J Cataract Refract Surg, 2011, 37(1): 13-18. doi:10.1016/j.jcrs.2010.07.014. [35] Rayner SA, Bhikoo R, Gray T. Spherical implantable collamer lenses for myopia and hyperopia: 126 eyes with 1-year follow up[J]. Clin Experiment Ophthalmol, 2010, 38(1): 21-26. doi:10.1111/j.1442-9071.2010.02192.x. [36] Lisa C, Naveiras M, Alfonso-Bartolozzi B, et al. Posterior chamber collagen copolymer phakic intraocular Lens with a central hole to correct myopia: One-year follow-up[J]. J Cataract Refract Surg, 2015, 41(6): 1153-1159. doi:10.1016/j.jcrs.2014.10.030. [37] Rodríguez-Una I, Rodríguez-Calvo PP, Fernández-Vega Cueto L, et al. Intraocular pressure after implantation of a phakic collamer intraocular Lens with a central hole[J]. J Refract Surg, 2017, 33(4): 244-249. doi:10.3928/1081597X-20170110-01. [38] Alfonso JF, Fernández-Vega-Cueto L, Alfonso-Bartolozzi B, et al. Five-year follow-up of correction of myopia: posterior chamber phakic intraocular Lens with a central port design[J]. J Refract Surg, 2019, 35(3): 169-176. doi:10.3928/1081597X-20190118-01. [39] Kojima T, Kitazawa Y, Nakamura T, et al. Prospective randomized multicenter comparison of the clinical outcomes of V4c and V5 implantable collamer lenses: a contralateral eye study[J]. J Ophthalmol, 2018, 2018: 7623829. doi:10.1155/2018/7623829. [40] Matarazzo F, Day AC, Fernandez-Vega Cueto L, et al. Vertical implantable collamer Lens(ICL)rotation for the management of high vault due to Lens oversizing[J]. Int Ophthalmol, 2018, 38(6): 2689-2692. doi:10.1007/s10792-017-0757-2. [41] Lim DH, Lyu IJ, Choi SH, et al. Risk factors associated with night vision disturbances after phakic intraocular Lens implantation[J]. Am J Ophthalmol, 2014, 157(1): 135-141.e1. doi:10.1016/j.ajo.2013.09.004. [42] Kamiya K, Shimizu K, Saito A, et al. Comparison of optical quality and intraocular scattering after posterior chamber phakic intraocular Lens with and without a central hole(Hole ICL and Conventional ICL)implantation using the double-pass instrument[J]. PLoS One, 2013, 8(6): e66846. doi:10.1371/journal.pone.0066846. [43] Ferrer-Blasco T, García-Lázaro S, Belda-Salmerón L, et al. Intra-eye visual function comparison with and without a central hole contact Lens-based system: potential applications to ICL design[J]. J Refract Surg, 2013, 29(10): 702-707. doi:10.3928/1081597X-20130919-03. [44] Sanders DR, Vukich JA, Doney K, et al. U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopia[J]. Ophthalmology, 2003, 110(2): 255-266. doi:10.1016/s0161-6420(02)01771-2. [45] Fujisawa K, Shimizu K, Uga S, et al. Changes in the crystalline Lens resulting from insertion of a phakic IOL(ICL)into the porcine eye[J]. Albrecht Von Graefes Arch Fur Klinische Und Exp Ophthalmol, 2007, 245(1): 114-122. doi:10.1007/s00417-006-0338-y. [46] Sanders DR. Anterior subcapsular opacities and cataracts 5 years after surgery in the visian implantable collamer Lens FDA trial[J]. J Refract Surg, 2008, 24(6): 566-570. doi:10.3928/1081597X-20080601-04. [47] Shiratani T, Shimizu K, Fujisawa K, et al. Crystalline Lens changes in porcine eyes with implanted phakic IOL(ICL)with a central hole[J]. Albrecht Von Graefes Arch Fur Klinische Und Exp Ophthalmol, 2008, 246(5):719-728. doi:10.1007/s00417-007-0759-2. [48] Kawamorita T, Uozato H, Shimizu K. Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular Lens with a central perforation[J]. Albrecht Von Graefes Arch Fur Klinische Und Exp Ophthalmol, 2012, 250(6): 935-939. doi:10.1007/s00417-011-1850-2. [49] Packer M. The Implantable Collamer Lens with a central port: review of the literature[J]. Clin Ophthalmol, 2018, 12: 2427-2438. doi:10.2147/OPTH.S188785. [50] Shimizu K, Misawa A, Suzuki Y. Toric intraocular lenses: correcting astigmatism while controlling Axis shift[J]. J Cataract Refract Surg, 1994, 20(5):523-526. doi:10.1016/s0886-3350(13)80232-5. [51] Lee H, Kang DSY, Choi JY, et al. Rotational Stability and Visual Outcomes of V4c Toric Phakic Intraocular Lenses[J]. J Refract Surg, 2018, 34(7):489-496. doi: 10.3928/1081597X-20180521-01. [52] Hyun J, Lim DH, Eo DR, et al. A comparison of visual outcome and rotational stability of two types of toric implantable collamer lenses(TICL): V4 versus V4c[J]. PLoS One, 2017, 12(8):e0183335. doi: 10.1371/journal.pone.0183335. eCollection 2017. [53] Sheng XL, Rong WN, Jia Q, et al. Outcomes and possible risk factors associated with Axis alignment and rotational stability after implantation of the Toric implantable collamer Lens for high myopic astigmatism[J]. Int J Ophthalmol, 2012, 5(4): 459-465. doi:10.3980/j.issn.2222-3959.2012.04.10. [54] Pérez-Vives C, Ferrer-Blasco T, Madrid-Costa D, et al Visual quality comparison of conventional and Hole-Visian implantable collamer lens at different degrees of decentering[J]. Br J Ophthalmol, 2014, 98(1):59-64. doi:10.1136/bjophthalmol-2013-303787. [55] Park MJ, Jeon HM, Lee KH, et al. Comparison of postoperative optical quality according to the degree of decentering of V4c implantable collamer lens[J]. Int J Ophthalmol, 2017, 10(4):619-623. doi:10.18240/ijo.2017.04.19. [56] Martínez-Plaza E, López-Miguel A, Fernández I, et al. Effect of central hole location in phakic intraocular lenses on visual function under progressive headlight glare sources[J]. J Cataract Refract Surg, 2019,45(11):1591-1596. doi: 10.1016/j.jcrs.2019.06.022. |
[1] | 代诚李宾中. 多焦点软性角膜接触镜应用研究进展[J]. 山东大学耳鼻喉眼学报, 2022, 36(5): 100-105. |
[2] | 冯燚源,杨晶,杨洪斌. 220例颈深间隙感染临床分析[J]. 山东大学耳鼻喉眼学报, 2022, 36(2): 51-57. |
[3] | 张陶然,王薇,李明铭,黄映湘. IVR治疗mCNV患者黄斑中心凹下脉络膜厚度分析[J]. 山东大学耳鼻喉眼学报, 2022, 36(2): 68-71. |
[4] | 彭娇,钟定娟,陈蛟,左筠,王华. 光学区直径与暗瞳直径的关系对不同程度近视患者SMILE术后视觉质量的影响[J]. 山东大学耳鼻喉眼学报, 2022, 36(2): 100-107. |
[5] | 李莹. 重视角膜屈光手术操作规范及并发症防治[J]. 山东大学耳鼻喉眼学报, 2021, 35(6): 1-6. |
[6] | 厉斌,方学军,吴德,黄敏. 基于NK公式和KS公式预测ICL术后早期拱高的一致性研究[J]. 山东大学耳鼻喉眼学报, 2021, 35(6): 33-41. |
[7] | 张颖,雷玉琳,马志兴,杨星花,张静,侯杰. SMILE联合快速角膜交联术后角膜光密度的早期临床观察[J]. 山东大学耳鼻喉眼学报, 2021, 35(6): 52-58. |
[8] | 刘艺,于明坤,孙伟,邵震,胡媛媛,毕宏生. 角膜塑形术控制儿童近视有效性与安全性的Meta分析[J]. 山东大学耳鼻喉眼学报, 2021, 35(6): 92-100. |
[9] | 次仁琼达, 吴元. 中毒性表皮坏死松解症导致眼部远期并发症1例[J]. 山东大学耳鼻喉眼学报, 2021, 35(6): 147-150. |
[10] | 冉宏运,蒋可可,张杰. 早产儿视网膜病变患儿屈光影响因素研究进展[J]. 山东大学耳鼻喉眼学报, 2021, 35(5): 118-124. |
[11] | 赵雅铭,石崧. 以急性会厌炎为首诊的3例颈部坏死性筋膜炎病例报告并文献复习[J]. 山东大学耳鼻喉眼学报, 2021, 35(4): 12-16. |
[12] | 岳鹏程,杜秋萱,孔玲,乔镇涛. 未矫正近视性屈光参差患者双眼间调节力对照研究[J]. 山东大学耳鼻喉眼学报, 2021, 35(4): 76-80. |
[13] | 刘凌,张美霞. 近视的药物治疗[J]. 山东大学耳鼻喉眼学报, 2021, 35(4): 123-128. |
[14] | 孙川,刘亚群,何双八,张庆翔. 低温等离子辅助经鼻切除前中颅底肿瘤17例[J]. 山东大学耳鼻喉眼学报, 2021, 35(2): 55-59. |
[15] | 魏佩佩,李灿. 多焦点人工晶体植入术后的视觉质量及并发症[J]. 山东大学耳鼻喉眼学报, 2021, 35(2): 141-146. |
|